SERVICE & INSTALLATION MENU
Element
Optional function
K9
Not used
KA
Not used
Setting Position of Motion
L1
Sensor
L2
Not used
Operation of the louvers in
L3
energy-saving Thermo-OFF
(Cooling / Dry mode)
Fan acceleration in energy-
L4
saving Thermo-OFF (cooling
mode)
Louver swing operation
L5
during energy-saving forced
Thermo-OFF
L6
Not used
L7
Not available
L8
Not used
L9
Not used
LA
Not used
Lb
Not used
52
PMML0601 rev.0 - 07/2022
Individual
Settings
setting
00
-
-
01
00
-
-
01
00
A
01
B
02
-
03
D
00
01
-
-
02
03
Direct air blow Low (factory setting)
00
Direct air blow Medium
01
O
Direct air blow High
02
03
Disabled
00
Function disabled (factory setting)
O
01
Function enabled
00
Function disabled (factory setting)
O
01
Function enabled
00
-
-
01
"- -"
permanent
00
-
-
01
00
-
-
01
00
-
-
01
00
-
-
01
Setting conditions
Description
Use at 00 conditions
Use at 00 conditions
-
Use at 00 conditions
Power save must be ON in
order to use this function (L5
must be set to 01).
This function is used to establish
louver swinging operation
ranging from continuous swing
to static operation.
Low: Continuous louver swing.
Medium: Louver swing
with intermittent stops for
20/40 seconds.
High: Louver stopped at full
opening position, according to
the setting of CF.
This function increases fan
speed by one step to prevent
the loss of comfort due to the
forced Thermo- OFF for energy
saving during cooling operation.
This function is used to enabled
the setting of function L3.
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions