Section 5, Compressor Lubrication - Separation, Filtration And Controls - Gardner Denver VS200-250B Operating And Service Manual

Variable speed single stage stationary base-mounted compressor
Table of Contents

Advertisement

SECTION 5
COMPRESSOR LUBRICATION – SEPARATION, FILTRATION AND
CONTROLS
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the compressor package before removing valves, caps, plugs,
fittings, bolts and filters.
High temperature operation can cause damage to equipment or personal injury.
Do not restart the unit repeatedly after high temperature shutdown. Find and
correct the malfunction before resuming operation.
COMPRESSOR OIL SYSTEM – Lubricating oil is employed to absorb the heat of compression, lubricate
moving parts and seal internal clearances between the rotor and air cylinder. Pressure differential
between the air/oil reservoir and various injection points is used to flow oil through the package.
Oil exits the air/oil sump and is then routed to the heat exchanger and the thermal mixing valve, where
cold (oil cooler branch) and hot (bypass branch) are mixed to a temperature that will avoid water vapor
condensation within the oil system. Tempered oil is sent to the oil filter for cleaning, then onto injection.
The injected oil absorbs heat from compression while progressing through the compression chamber and
is then discharged back into the oil separation chamber as a mixture of liquids and aerosols (oil) and gas
(air).
Centrifugal action within the air/oil reservoir separates the bulk of the oil from the air, where it is collected
and readied for the next cooling cycle. The compressed air and aerosols continue through a coalescing
filter, where all but 2 ppm of oil concentration is removed from the compressed air and discharged to the
aftercooler.
RECOMMENDED LUBRICANT – The Gardner Denver compressor is factory-filled with AEON 9000SP
lubricant. This lubricant is formulated to the highest quality standards and is factory-authorized, tested
and approved for use in our rotary screw compressors. AEON 9000SP lubricant is available through your
authorized Gardner Denver compressor distributor.
OIL SPECIFICATIONS - The factory fill compressor lubricant is Gardner Denver AEON 9000SP
lubricating coolant for all-year-round operation. This is a polyalphaolefin (PAO) synthetic lubricant
specially formulated for rotary screw compressor service.