4.2.2 Horizontal installation, NB, NBG
For inspection and repair, allow suitable
clearances for pump or motor removal.
Pumps fitted with motors up to and including 4 kW
require a 0.3 m clearance behind the motor.
Pumps fitted with motors of 5.5 kW and up require
a 0.3 m clearance behind the motor and at least a
1 m clearance above the motor to allow the use of
lifting equipment.
NB pumps with base frame must have the same
clearance as pumps with motors from 5.5 to 200
kW.
Clearance behind the motor
Motor
0.25 - 4 kW
B
Clearance behind and above the motor
Minimum clearance
Motor
5.5 - 200 kW
0.3 m
A
Minimum clearance, A
0.3 m
A
A
B
1 m
4.2.3 Minimum clearance of MTB
For inspection and repair, allow suitable
clearances for pump or motor removal.
Motor and pump head removal
Minimum clearance, X [mm]
P2
Pump
[kW]
Motor only
50 Hz
MTB 50-200
3.0
60
5.5
MTB 65-160
80
7.5
11
MTB 65-200
100
15
60 Hz
3.0
60
MTB 50-200
4.0
5.5
80
MTB 65-125
7.5
80
11
MTB 65-160
110
15
X
Motor and pump
head
140
100
100
140
100
100