Page 1
DC0043E-05 30 kW DC Power Supply Controller Model DC power supply DPG-30R Controller DPG-MC60R DPG-MC120R DPG-MC240R 5th Edition: July 14, 2023 ULVAC Inc. * Read this manual before using the system. Store this manual carefully so that it can be used at anytime.
Page 2
The content of this manual may differ from the system being used due to system improvements. If you have any questions and items of concern, contact your exclusive ULVAC dealer. Please operate the system safely and administer it correctly.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] Introduction 1. Safety precautions Most accidents are attributed to carelessness during operation, inspection, maintenance, or repair. Failure to comply with the safety precautions or neglecting to anticipate danger causes accidents to happen more easily.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] Introduction 2. Safety symbols Safety symbols are used throughout this manual and labeled on the system to call the operator's attention to safety. The terminology used in safety symbols is classified below.
Page 5
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] Introduction 1) Power supply unit safety symbols The safety symbols below are used on the power supply unit. Power supply unit safety symbol list Power supply unit safety Description symbol Warning: Be careful of heavy item handling ・There is a risk of injury...
2. If an on-site response is required, consult separately with ULVAC or the nearest sales office or dealer. 2) For direct export transactions ULVAC will send a replacement system, or you will return the system to ULVAC or the nearest ULVAC service center where it will be repaired. Return shipping expenses are borne by the customer.
If you have determined there is a malfunction or if you have any questions, contact to ULVAC. When contacting ULVAC, please inform us of the names or model numbers of the products, the serial numbers, and the symptoms of the problem in as much detail as possible.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] Introduction 7. RoHS compliance 1) European Union RoHS EU RoHS non-compliant parts list Hazardous substance or element Hexavalent Polybrominated Part name Lead Mercury Cadmium Polybrominated chromium diphenyl (Pb) (Hg) (Cd) biphenyls (PBB)
3-4. W ....................29 IRING AND CONNECTIONS 3-4-1. Cables to connect to the DPG-30R and DPG-MC60R ........29 3-4-2. Cables to connect to the DPG-30R and DPG-MC120R ........30 3-4-2. Cables to connect to the DPG-30R and DPG-MC240R ........31 3-4-3.
Page 10
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] Contents 4-1. DPG-30R DPG-MC60R/120R/240R ............. 33 OPERATIONS 4-1-1. Operations ....................... 33 4-1-2. Controller configuration ..................33 4-1-3. System power each power setting ..............34 4-1-4. Timing chart for power supply system control ........... 34 4-1-5.
Danger This power supply handles high voltages. Internal power supply inspections and repair are handled by ULVAC or ULVAC Group representatives. Therefore, do not remove the power supply or controller panels under any circumstances. Danger When replacing the power supply, always turn off the upstream breaker and remove the...
To order parts, ask questions about the system, and to make inquires related to system malfunctions, first verify the system information and then contact ULVAC or an exclusive dealer. Especially when you have determined the system has malfunctioned, inform us of the system information along with the system's history and symptoms in as much detail as possible.
(PLC). 2-2. Features A single controller can control up to 2 power supplies (DPG-30R) by using the DPG-MC60R controller A single controller can control up to 4 power supplies (DPG-30R) by using the DPG-MC120R controller ...
The DPG-30R input cable, output cable, and control cable are sold separately. Cables are provided by ULVAC. Inform us separately of the necessary cable lengths. At 5m units than 5m, output cable length is available to 10m standard. I correspond with standard 4m With regard to the input cable.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-3-2. 120 kW power supply system configuration example * The DC power supply input terminal and output terminal are both located on the back of the power supply. DC PS controller...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-3-3. 240 kW power supply system configuration example AD I/F DC PS Controller DPG-MC240R 1Φ+GND Input 100-240 VAC Vacuum chamber Output DC Power Supply Anode 3Φ+GND Input 380-480 VAC Output...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-4. DC power supply unit (DPG-30R) specifications Table 2-1 Electrical specifications (single unit specifications) Item Specification Input rated voltage 380 to 480 VAC Input voltage fluctuation range 342 to 528 VAC...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview * Insert a 70 A circuit breaker in the input(Recommendation breaker manufacturer: fujielectric:BW100EAGU 3P 70A) U ser I/F D C P S C o ntro ller D P G -M C 120R 1Φ...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-6. External control pin assignments 2-6-1. External control terminal (controller AD-IF connector) When performing external control, see "Table 2-7 External control signal connection equivalent circuits" and connect the external control terminal to an external control device such as a PLC.
Page 20
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview changes by the number of power supplies.see Table 4-1 changes by the number of power supplies.see Table 4-1 During P control:becomes the corresponding system power for a output setting voltage level 0 to 10 V...
Page 21
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview • When only the power supply is connected Table 2-6 External control terminal pin assignments when only the power supply is connected Pin No. Signal name Type Voltage level Return...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-6-2. External control terminal supplementary description The external control terminal wiring carries a risk of noise interference if the wiring is long. ULVAC recommends the measures below. 1. recommends shielded twisted pair cables.
Page 23
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview Signal Signal Equivalent circuit type DPG-MC60R,120R, 240R PLC side AD INTERFACE side ISO AMP Analog output COM A COM A COM A DPG-MC60R,120R, 240R AD INTERFACE side COM L COM L COM L PLC side 0.01μF 2. 2 kΩ...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-6-3. Recommended digital I/O connection circuits DPG-MC60R,120R,240R AD INTERFACE +24 V 100Ω Digital output COM D COMD Digital input +24 V IN +24 V COM D 2.2 kΩ 5mA or more COMD Figure 2-5 Recommended digital I/O connection circuits 2-6-4.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 2. Overview 2-6-6. Selecting the ARCDELAY mode This section lists the signals to perform ARCDELAY ON/OFF selection via the AD I/F connector. ARCDELAY mode can be enabled by setting six pins of an AD I/F connector as Low.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3. Setup This chapter describes the necessary preparation from when you receive the system until it can be used and precautions about the system. 3-1. Unpacking Unpack the system and remove the components.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-2. Part names and functions 3-2-1. DC power supply front and rear panels ① ② Figure 3-2 DC power supply front panel...
Page 28
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup ⑨ ③ ④ ⑤ ⑥ ⑩ ⑪ ⑦ ⑧ Figure 3-3 DC power supply rear panel Table 3-1 DC power supply front and rear names and functions Name Configuration Function...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-2-2. Controller front and rear panels Front panel Figure 3-4 Controller front panel (Top: MC-60R,Middle: MC-120R, bottom: MC240R) Table 3-2 Controller front names and functions Name Configuration Function 1. LOCAL monitor LED (green) Turns on during LOCAL control.
Page 30
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup Name Configuration Function Turns on the HARC, MARC LEDs and displays the number of ARC occurrences in the 7-segment LEDs. When the number of ARC occurrences is over 9999, 9999 is displayed as flashing.
Page 31
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup Rear panel Figure 3-5 Controller rear panel (Top: MC-60R,Middle: MC-120R, bottom: MC240R) Table 3-3 Controller rear names and functions Name Configuration Function D-sub 37-pin 1. DC1 to DC8 Communicates signals with the DC power supplies.
Page 32
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 10. MX LINK Connector Not used. 11. Nameplate Shows the model and serial number 12. Specification label - Indicates the model, input specification, weight, etc. *1 13. RS232C Connector Not used.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup ・3-2-3. Arc link terminal pin assignments On the reference to "Table 2-7 external control signal equivalent circuit connection" to use the ARC LINK terminal, Connected to an external control device such as a PLC Table.3-4...
The actually used capacity corresponds to the number of power supplies. Power for the controller is separately required. * ULVAC recommends isolating the AC input for both the DC power supplies and the controller with isolating transformers.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-3-3. Mounting the DC power supply and controller Always mount the DC power supply and the controller in a rack before use. See Figure 3-7 and Figure 3-8 for the positions to drill the mounting holes.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-3-4. DC power supply and controller isolation bushings When mounting the DC power supply and the controller in a rack, isolate the controller from the rack by attaching isolation bushings as shown in Figures 3-9 and 3-10. Isolate the power supply from the rack in the same manner.
Page 37
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup Figure 3-10 Isolation bushing attachment positions (controller) * Select a location as dust- and vibration-free as possible. Avoid installing the units in a location with an uneven floor surface.
Page 38
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup For ventilation, ensure that there is plenty of clearance around the DC power supply as shown in Figure 3-11. Create a structure that can adequately ventilate the rack so the temperature and humidity in the rack do not exceed the specifications.
Do not connect the cables with the system energized under any circumstances. When connecting and disconnecting cables, ensure that the breakers for the input lines supplying the DC power supplies and the controller are turned off. 3-4-1. Cables to connect to the DPG-30R and DPG-MC60R AC in 100-240 V...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-4-2. Cables to connect to the DPG-30R and DPG-MC120R AC in 100-240 V Controller DPG-MC120R AD IF Control DC output 1 AC in 380-480 V Control DC output 2 AC in...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 3. Setup 3-4-2. Cables to connect to the DPG-30R and DPG-MC240R AC in 100-240 V Controller DPG-MC240R AD IF Control DC output 1 AC in 380-480 V Control DC output 2 AC in...
This DC power supply system has eight types of configurations from 30 kW to 240 kW. The connection for the control cable between the DPG-30R and the DPG-MC60R (120R,240R) is made by connecting the cables from 1 in order. A configuration error will occur on the controller when the power setting switch position is incorrect or the cable connection points are incorrect.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 4. Operation This chapter describes how to operate and use the system. 4-1. DPG-30R and DPG-MC60R/120R/240R operations 4-1-1. Operations This power supply system is connected to an external control device such as a PLC and that device controls the power supplies.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 4-1-3. System power each power setting To match the system configuration of the power supply, rated output values for LEVEL signal (DCV, DCI, DCP) and each monitor signal will change. Please refer to the table below.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 4-1-5. Controller display Operations are performed with the procedures below. Based on "Figure 3-14 Power supply and external PLC connections" in the previous section, verify the connections for the cables and connectors, and verify that the power setting is accurately configured.
Page 46
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 7. SET LED turns on for 0.2 seconds HARC MARC 8. MARC LED turns on for 0.2 seconds HARC MARC MARC 9. The CPU firmware version turns on for 1.0 second ex: Ver 00.01...
Page 47
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation * The display below is shown When the power supply is not connected to the controller HARC MARC 2) Power/voltage/current/LEVEL monitor display When the startup display is finished, the display changes to the main screen.
Page 48
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 3) Change the display method By quickly pressing the DSP SW, the display changes in the following order. (Initial) kW monitor & V monitor -> A monitor & V monitor ->...
Page 49
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 4) Output value setting method (during LOCAL only) Only during LOCAL, you can set the output values by pressing and holding the DSP SW. The display changes to (Initial) kW monitor & V monitor ->...
Page 50
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation Quick press △ SW 3 times HARC MARC Flashing Flashing Quick press ENT SW HARC MARC 5) Error display example When the 1st error is E303 and the second error is E321...
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation MARC HARC 3. Monitor display The display returns to the monitor display. MARC HARC When the error is reset, the error information for display usage between the last error reset (or from when the power was turned on) up to this error reset is discarded.
Page 52
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation Table 4-4 Controller warning display Warning name Code Warning details Classification (*) V_OUT_OVER C300 Occurs when the output voltage has exceeded 1700 V Occurs when a short circuit on the load side has been...
Page 53
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 4. Operation 4-1-7. Behavior of more than one error occurs If multiple errors occur, and then output by switching up to a maximum of 20 error code in chronological order every 3 seconds.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 5. Maintenance 5. Maintenance The chapter describes necessary maintenance so the system can be used for years to come. If you neglect maintenance, the system will wear out more quickly, which may cause it to stop working.
5. Maintenance 5-2. Recommended parts for replacement In order to use the power supply for a long period of time, ULVAC recommends a periodic overhaul. See Table 5-1 below for parts that we recommend you replace during the periodic overhaul.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 6. Troubleshooting 6. Troubleshooting This chapter explains corrective action when problems occur. 6-1. Troubleshooting When a problem occurs, please perform an initial diagnostic with the LED indicators on the front panel of the power supply and the controller display according to the method below.
Page 57
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 6. Troubleshooting Symptom Possible cause Action TEMP ERROR Overheating in the inverter or If there is no cause such as a drop in rectification circuit power supply cooling efficiency near the power supply's front or rear, replace the power supply.
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials 7. Reference materials The following materials on the DPG-30R and DPG-MC60R(MC120R/MC240R) are included with this manual as a reference. (1) DPG-30R external view (2) DPG-MC60R external view (3) DPG-MC120R external view...
Page 59
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-1 DPG-30R external view...
Page 60
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-2 DPG-MC60R external view...
Page 61
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-3 DPG-MC120R external view...
Page 62
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-4 DPG-MC240R external view...
Page 63
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-5 DPG-30R warning label locations...
Page 64
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Figure 7-6 DPG-MC60R warning label locations...
Page 65
DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R] 7. Reference Materials Weight warning Danger high voltage Nameplate label Weight label Figure 7-6 DPG-MC120R, DPG-240R warning label locations...