08 - OPERATION

When the equipment is switched on, it must emit 3 short tones on the buzzer and on the LED (if it emits 2 long tones,
there is a communication problem with the Mifare RF circuit and specialized assistance must be sought).
After this indication, the equipment is already in operation, keeping the LED fixed in blue.
If the equipment is connected to a WeGo Converter, the LED on the equipment will dim, alternating between on and
off, simulating "breathing".

09 - STATUS

10 - USER ENROLLMENT

Press the
Enter/Menu key
for 5 seconds
Enter ID
of the user
+ Enter
NOTES: The user must enter a user identification number (ID) of a maximum of 8 digits and at least 1 digit, a pass-
word of a maximum of 8 digits and at least 1 digit, and may have a card enrolled (swipe the card while in the enroll-
ment menu).

11 - REMOVAL OF USERS

NOTES: The user must enter a user identification number (ID) of an enrolled user. This process erases all user infor-
mation.
SIGNALLING LED COLOR
Blue
Yellow
Red
White
Enter password for
programming
(the default is 2413) + Enter
The
Yellow LED
Swipe the
user's RFID
card
The blue and
green
LED will flash
Press the
Enter/Menu key
for 5 seconds
Type 92
+ Enter
The
Red LED
Waiting for password
In setup menu
Activates the
fixed
Yellow LED
Enter the user
password
+ Enter
The blue and
green
LED will flash
Enter password for
programming
(the default is 2413) + Enter
The
Yellow LED
Enter ID
of the user
+ Enter
ENGLISH
STATUS
In operation
Fault
Type 91
+ Enter
The
Green LED
The Green LED
will flash 2 times
along with audible
warning confirming
registration
Activates the fixed
Yellow LED
The green LED will flash
2 times along with an
audible warning con-
firming un-enrollment
27