Configuring the Unit Using the Internal Switches
Configuring the Unit Using the Internal Switches
496-15104
"
4-2
Use internal Switchpacks S1 and S2 to manually configure the unit. Use
Figure 4-1
to locate Switchpacks S1 and S2.
!
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from
damage due to electrostatic discharge (ESD) during normal operation.
When performing installation procedures, however, take proper static
control precautions to prevent damage to equipment. If you are not
sure of the proper static control precautions, contact your nearest
sales or service representative.
Procedure
To configure the unit using internal Switchpacks S1 and S2:
1. Power off the unit. Remove the enclosure cover by pushing a flat-blade
screwdriver through the slots on both sides of the housing to free the four
inner latches.
2. Locate Switchpack S1 on the circuit board using
3. Set Switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.
4. After you enable the switchpacks, you must set the switches to your desired
configuration. Refer to
5. Replace and secure the cover.
6. Power on the board to reset and enable the new configuration.
August 1999
Figure 4-1
and
Tables 4-1
Figure
4-1.
through 4-10.
7970-A2-GB20-00