Table 7. Telnet Session Options (2 of 2)
Disconnect Time (Minutes)
Possible Settings: 1 – 60
Default Setting: 5
Number of minutes of user inactivity before a Telnet session terminates
automatically. Time out is based on no keyboard activity.
Table 8. Communication Protocol Options (1 of 2)
Node IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the Node IP address.
Node Subnet Mask
Possible Settings: 000.000.000.000 – 255.255.255.255
Default Setting: 000.000.000.000
Specifies the Node Subnet Mask.
Default Network Destination
Possible Settings: None, COM, DSL
Default Setting: None
Specifies where the default management network is connected. For example, if your
default network is connected to the COM port, select COM as the default
management network destination.
Communication Port IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the unit's Communication Port IP Address when the unit is configured as a
network communication link.
Communication Port Subnet Mask
Possible Settings: 000.000.000.000 – 255.255.255.255
Default Setting: 000.000.000.000
Specifies the unit's Communication Port Subnet Mask when the unit is configured as
a network communication link.
19