Paradyne Hotwire 7974 Installation Instructions Manual page 16

Standalone termination unit
Table of Contents

Advertisement

Table 5. System Options
DSL Mode
Possible Settings: LTU, NTU
Default Setting: NTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE:
Changing this option will reset the termination unit.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed so that control can be regained after a test is accidentally
executed.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Telco Initiated Loopback (Models 7974 and 7984)
Possible Settings: Enable, Disable
Default Setting: Enable
Determines if the unit will respond to loopback commands on the DSX-1 interface.
Remote Telco Line Loopback (Models 7974 and 7984)
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if the unit will perform a Telco-initiated loopback on just the local unit or if
the loopback will be performed on the remote DSL unit.
16