Component Identification
Electrical Connections
This equipment must be grounded. All electrical wiring
must be done by a qualified electrician and comply with
all local codes and regulations.
NOTICE
To help prevent heater damage, avoid spilling liquids
onto electrical components.
Requirements For All Installations
•
The user must provide external over-current protec-
tion. For installations in the United States and Can-
ada, a branch circuit breaker must be used for
over-current protection. The maximum recom-
mended circuit breaker size is 15 amps.
F
. 5: Connector
IG
10
Power Cable Connections
The heater power cable uses a 3 conductor cable and a
NEMA L6-20P twist lock connector. If another connector
is used, follow the table below for correct wiring.
Cable Color Code
Black or Brown
White or Blue
Green or Green/Yellow
Green or Green/Yellow
White or Blue
Function
Line (Mains)
Neutral
Protective
Ground/Earth
Black or Brown
ti20030a
3A2824B