Is there a way to block an automatic correction bonus when you know you will be active and you have the exercising condition set?
1 comments:
Mr. Anderson
May 28, 2025
To block the automatic correction bolus when exercising with the Tandem X2 Control-IQ Technology, disable the Exercise Activity setting. Automatic correction boluses can be delivered once per hour when Exercise Activity is enabled, but not when it is disabled.
This answer is automatically generated
Carol
March 18, 2025
How do I turn off Alarms
Related Manuals for Tandem T:SLIM X2 Control-IQ Technology
Summary of Contents for Tandem T:SLIM X2 Control-IQ Technology
Page 1
T:SLIM X2 INSULIN PUMP Control-IQ Technology 4:45 PM 14 Nov 100% 235 u mg/dL This Quick Reference Sheet will teach you how to turn Control‑IQ INSULIN ON BOARD 1.1 u 1:09 hrs ☛ technology on. Flip to OPTIONS BOLUS the back to learn how Control‑IQ technology adjusts insulin delivery.
Page 2
Control-IQ mg/dL 180 lbs Weight 29 u Total Daily Insulin INSULIN ON BOARD 1.1 u OPTIONS BOLUS Control‑IQ technology is on. to save the settings. Tap the Tandem logo on the face of the pump to return to the Home screen.
Explanation of Icons 4:45 PM 14 Nov 100% 235 u mg/dL INSULIN ON BOARD 1.1 u OPTIONS BOLUS Insulin Adjustments Delivers basal rate from Personal Profile Increases basal insulin delivery Delivers an automatic correction bolus † Decreases basal insulin delivery Stops basal insulin delivery Activity States Sleep Activity enabled...
Page 4
112.5 Predicted Glucose Levels mg/dL Delivers 112.5 Insulin Delivery Decreases Stops Maintains Increases mg/dL Delivers Insulin Delivery Decreases Stops Maintains Increases Activity Settings Responsible Use of Control-IQ Technology Control-IQ technology features two optional settings that adjust Control-IQ technology does not prevent all high and low blood glucose events, and is not a substitute for meal boluses and active treatment ranges for more targeted control.
Need help?
Do you have a question about the T:SLIM X2 Control-IQ Technology and is the answer not in the manual?
Questions and answers
Is there a way to block an automatic correction bonus when you know you will be active and you have the exercising condition set?
To block the automatic correction bolus when exercising with the Tandem X2 Control-IQ Technology, disable the Exercise Activity setting. Automatic correction boluses can be delivered once per hour when Exercise Activity is enabled, but not when it is disabled.
This answer is automatically generated
How do I turn off Alarms