ACCESSORIES INSTALLATION
98
How to Install Remote Temperature Sensor
[Parts of Remote Temperature Sensor]
Cable
Follow below procedures step 1 ~ step 6.
Step 1. Decide where the remote temperature sensor is Installed. Then, Determine the location
and height of the fixing screws in fig. 1 (Interval between the screws : 60 mm)
Step 2. Check if the power of the unit is turned off.
Step 3. Disassemble front panels and distinguish control box(Indoor) of the unit.
Step 4. Insert temperature sensor into PCB(CN_ROOM) and fix the sensor firmly in fig. 2.
Step 5. The Connection wire does not matter if you change the color of the wire because of
nonpolar.
Fixing screws
60 mm
[fig. 1]
Step 6. Integrate the remote temperature sensor with the screws as the order of arrows.
Screw(to fix remote sensor)
Indoor PCB
Fixing the Remote Sensor
1
Installation Manual
CN_ROOM
[fig. 2]