INSTALLER SETTING
156
In this mode, setting temperature will follow outdoor temperature automatically. This mode adds
the cooling season function to the conventional weather dependent operation mode.
Auto-Adjustable
Target Temperature
Water Temp Target: LW/EW1
Room Air Temp Target: RA1
Water Temp Target: LW/EW2
Room Air Temp Target: RA2
Water Temp Target: LW/EW3
Room Air Temp Target: RA3
Water Temp Target: LW/EW4
Room Air Temp Target: RA4
NOTE
DHW mode can be operated independently of seasonal auto temp mode.
of weather dependent operation
Out1
Out2
Temperature profile
Out3
Heating
Cooling
Outdoor air
temperature
Out4