Remove the cable clip (4).
Remove the cover cap (5) on the socket.
Unscrew the four socket screws (6).
Pull the socket (7) out of the angle bracket (8).
@
Open the box and remove the two baskets.
©
Unscrew the two screws (9) and remove the detec-
tor's (11) anchoring clip (10).
ο
Unscrew the four screws (12) on the Peltier block (13)
and remove this by pulling inwards.
©
Remove the ventilator cover (chapter 21).
ο
Disconnect the plug (14) from the connector shell on
the ventilator (15).
o
Unscrew the four screws (16) and remove the venti-
lator (15) together with the mounting plates.
Installation of a new Peltier block is in reverse order, whereby it is important that the wires are connected up
correctly to the 12-channel plug (same figures for wires and plug).
Before assembling the Peltier block, make sure the sealing (17) is fitted correctly.
REPLACING THE OUTER VENTILATOR
©
Remove the cover (chapter 16).
©
Disconnect the plug (1) from the connector shell on
the ventilator.
©
Unscrew the four screws (2) and remove the ventila-
tor (3).
@
Remove the four spacers (4) from the ventilator.
Installation of a new ventilator is in reverse order.
When connecting up the plug, make sure the terminals are
connected correctly (,,+" on the plug to ,+" on the connec-
tor shell).
-16-