Remove the cable clip (9).
©
Unscrew the six screws (10) and remove the combination
circuit unit (11).
Installation of anew
combination
circuit unit is in reverse order.
When connecting up wires (5) and (6), make sure the wiring is
correct (same figures for wires and 12-channel plug)
REPLACING THE VENTILATOR COVER
@
Open the box and remove the two baskets.
©
Unscrew the two screws (1) and remove the ventila-
tor cover (2).
Installation of a new cover is in reverse order.
REPLACING THE PELTIER BLOCK
-15-
Remove the cover (chapter 16).
Remove
the
cover
plate
from
the
electronic
equipment
casing
and
disconnect
the
battery
cable plug connection (chapter 18).
Pull the 12-channel plug (1) out of the connection
strip X101
on the control board.
Remove
wires 1 to 4 and 7 to 12 from the 12-
channel plug (1).
Unscrew the union nut (2).
Remove the cable (3), together with the screw fit-
ting, from the casing.