Connecting to the DDS (or LADS) Network
NOTE:
Before connecting the DSU to the DDS network, ensure that approved primary
protectors have been installed on the circuit in accordance with Article 800 of the
National Electric Code, NFPA 70, in the United States and Section 60 of the
Canadian Electric Code, Part 1, in Canada.
Follow these steps to connect the DSU to the network.
Procedure
1. Plug the DDS network interface cable into the DSU jack labeled LINE.
— U.S. – select either end of the cable
— Canada – select the 8-pin end
2. Plug the other end of the cable into the modular jack (USOC RJ48S) provided by
the circuit provider.
If the remote DSU is also connected to the network, the DSU's green OK indicator lights
and the Alrm indicator goes off. The Health and Status screen no longer displays a
No Signal message.
If connecting the DSU to a LADS network, there are distance limitations that govern the
use of DSUs on the network. Table 2 summarizes these limitations.
Model 3615 DSU DDS (LADS) Network Connection