Paradyne COMSPHERE 3610 Replacement Manual page 16

Data service units documentation replacement
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Specifications
RINGER EQUIVALENCE NUMBER (REN)
APPROVALS
DOC
Certification (PSTN)
Load Number
APPLICATION
MODULATION AND FREQUENCY
CHANNEL EQUALIZATION
Transmitter
Receiver
COMMUNICATION LINE
DATA RATES
DBM COMPATIBILITY
RECEIVE VF INTERFACE
Dynamic Range
V.34 2-wire PSTN
Impedance
SWITCHED NETWORK INTERFACE
3610 DSU
3611 DSU
TRANSMIT VF INTERFACE
Signal Level
V.34 2-wire PSTN
Impedance
3610-A2-GB43-20
Table 1-5
V.34 DBM and DBM-F Technical Specifications
DBM option 0.2B
230 6811 A
3
Full- or half-duplex data transmission via analog 2-wire Dial Network
(PSTN), point-to-point
At 28.8 kbps: ITU-T V.34
At 12 and 14.4 kbps: CCITT V.32bis, 1800 Hz
At 4.8 and 9.6 kbps: CCITT V.32, 1800 Hz
At 2.4 kbps: CCITT V.22bis, 2400 Hz
Compromise equalizer
Automatic adaptive equalizer
2-wire analog (PSTN) line
2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 21.6, 24, 26.4, and 28.8 kbps
If Call Setup is set for Callback or Password security, then the device is
compatible with a 3600 Series V.32 or V.34 DBM only.
If Call Setup is set for Alarm or None, then any V.32 or V.34 modem can be
used.
Also, V.22bis at 2.4 kbps can be used.
– 43 to –10 dBm
600
6-pin modular jack
Permissive: USOC RJ11C
(One or two) 50-pin connector
Permissive: USOC RJ21X
Permissive: – 9 dBm
600
December 1996
Technical Specifications
Criteria
1-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series