COMSPHERE 3550 Series Data Service Units
Async Rate: =Sync
Next
=Sync
1800
Asynchronous Rate . Specifies the rate of an asynchronous port. The asynchronous rate must be less than or equal to
the synchronous data rate of the port. Set the synchronous data rate for a port via the Port Speed (PrtSp) configuration
submenu. This configuration option is displayed only if Async Sync is enabled.
Option Verification: When 1800 bps is selected, the DSU verifies that the synchronous port speed is 2400 bps or
greater. If only one stop bit is used, the asynchronous rate cannot be equal to half the synchronous rate.
=Sync
Select for the asynchronous rate to be the same as the synchronous rate.
1800
Select the rate of the asynchronous port.
to 150
AsyncBit/Char: 8
Next
6
7
8
Asynchronous Bits per Character . Specifies the length of a character, including the parity bit but excluding the start and
stop bits. This configuration option is displayed only if Async Sync is enabled. If set to 10, the Stop Bits configuration
option only displays 1.
6 to 10 —
Select the asynchronous bits per character.
Stop Bits: 1
Next
1
2
Prev
Stop Bits . Specifies the number of stop bits in an asynchronous character. This configuration option is displayed only if
the Async Sync configuration option is enabled and AsyncBit/Char is set to 6, 7, 8, or 9. If AsyncBit/Char is set to 10,
only 1 stop bit appears.
1 to 2
Select the number of stop bits to be used.
Overspeed: 2.5
Next
1.25
2.5
Overspeed . Selects the overspeed range of the asynchronous-to-synchronous converter. This configuration option only
applies when Async Sync is enabled.
1.25
Select the basic overspeed range. Basic range provides 1.25 % overspeed in the DTE asynchronous data
rate.
2.5
Select the overspeed percentage for extended range. Extended range provides 2.5 % overspeed in the
DTE asynchronous data rate.
RTS Cntrl: DTE
Next
FrcOn
DTE
Request-to-Send Control . Controls the behavior of the internal RTS lead.
FrcOn
Select for the DSU to keep the internal RTS ON continuously. Any data appearing on the transmitted data
(TXD) lead from the DTE is transmitted immediately.
DTE
Select for the DSU to turn ON RTS when the external RTS is turned ON. CTS is turned ON or Off by the
external control signal RTS.
* The menu paths for Prt1 and Prt2 are identical.
5-24
Table 5-11
MUX (Port) Configuration Options*
1200
600
300
9
10
Prev
Prev
Prev
(2 of 4)
150
Prev
July 1999
3550-A2-GB20-40