Whirlpool ARISTON AKT 9020 B Manual page 13

Table of Contents

Advertisement

Available languages

Available languages

If a timer LED is lit in static mode this means that the relevant
timer has been programmed and its countdown is under way but
the time elapsed is not at the moment shown on the 7 segments
display.
On the 7 segment display of a timer not yet programmed the
symbol "00" is shown, with the timer warning light flashing. For an
already programmed timer the residual time is displayed.
If no setting is made within 10 seconds from the first selection of a
timer, (display remains "00"). If however one or more other timers
have been activated the display switches to the timer with the
lowest reset value. The value is shown on the 7 segment display
and the assigned LED flashes as shown in diagram 1.
To clearly highlight that a timer has been selected and can be
operated with the plus/minus keys, the 7-segment timer display
will flash.
SETTING TIMER VALUE
Following selection of the timer, the assigned warning light flashes
as described above. The countdown time for the desired timer can
be set with the Plus/Minus buttons.
Beginning with the Plus button the first displayed value goes to
"01" and increases in steps of 1 to a maximum of "99" (end of run).
Starting with the Minus key, the value displayed on the indication
jumps up, "99" and decreases in steps from 1 to "01". To reach "00"
the plus and minus keys can be pressed simultaneously.
In the case of permanent activation of the button there will be an
automatic acceleration of adjustment speed, meaning that the
time between one step and the next will be reduced as long as the
button is kept depressed.
Generally a timer sets off with the countdown if the latter has been
programmed with values not equal to 0. Example: the timer starts
with the release of the Plus button after having set the timer value
"01".
The timer settings take priority over service time delimitations in
the presence of high cooking level settings.
TIME EXPIRY/TIMER ALARM AND CONFIRMATION
When the set time has expired the timer alarm is triggered and any
assigned cooking area is switched off immediately.
The cooking level display indication "0" flashes in alternation with
the symbol "H" in the case of latent heat.
The 7-segment Timer display (24) indicates "00". The cooking zone
timer Led (eg 16) also flashes.
Timer alarms take priority. If on expiry of the time the user should
enter data, the current activation of the buttons will be used in
order to confirm the alarm.
The sound signal is activated (beeper).
The alarm signal lasts at most one minute, if the user does not
intervene earlier.
At the end of the minute or by pressing any key, the alarm signal is
suspended.
Both the sound and visual signals of the timer are deactivated.
If confirmation of the alarm takes place by pressing a button,
the sound signal is deactivated immediately and a button
confirmation beep is emitted. Depending on the moment of
confirmation, the signal of confirmation could coincide with the
alarm sound signal. In the case of alarm confirmation by means of
pressing a button, the actual function of the buttons will not be
carried out. To activate button function they must be released and
then reactivated.
EXCEPTION: ON/OFF
Button: in the case of alarm confirmation by means of the ON/OFF
button, the alarm signals will be deactivated 300 ms after activations.
If the button remains activated subsequently, the control will switch to
OFF mode after a total of 1 s.
SWITCHING OFF THE TIMER/MODIFICATION OF TIMER SETTINGS
It is possible to change the setting of the timer, in wait or active
modes, at any time after you have made the selection, by pressing
the + or - key.
The timer can be switched off by taking it to the "00" value, pressing
the Minus button or simultaneously pressing the Plus and Minus
buttons once.
Timers connected to the cooking areas are deactivated when the
cooking level in the assigned cooking area is taken to 0.
KEY LOCK LOCKING/ACTIVATION
Pressing the Key-Lock button in WAIT or ACTIVE mode locks the
keyboard. The Key-Lock warning light comes on in static mode.
The time schedule must be observed for activating the Key-Lock
button. The control goes on working in the previously set mode
but cannot be controlled with buttons other than the Key-Lock or
ON/OFF buttons. All the locked buttons are not commanded by
the control with regard to continuous activation.
SWITCHING OFF WITH THE ON/OFF BUTTON IS ALSO POSSIBLE IN
THE LOCKED STATE
The Key-Lock function incl. the light remains active until it is
deactivated by pressing the Key-Lock key again. Activation
deactivation of the Key- Lock function in OFF mode is not possible.
If programmed timers should be in function, the respective timer
alarms must be confirmed by depressing any button whatever,
without having to unlock the control previously.
If the key-lock is active, by pressing a key the word "lo" will appear
until the key-lock is deactivated.
KEY LOCK UNLOCKING/ DEACTIVATION
The new activation of the Key-Lock button in the WAIT or ACTIVE
mode involves the unlocking of the keyboard and the switching
off of the assigned Key-Lock warning signal. All the sensor buttons
can be once more activated.
OPERATING TIME LIMITATION
The touch control, if no commands are received, stops after a few
hours depending on the level set. N.B. Attention: in the case of
level p after 1 minute it passes to level 9 then the time of level 9 is
counted.
Cooking level
0
1
2
3
4
5
6
7
8
9
P
N.B.:
When one makes use of heating elements, we advise receptacles
with flat bottom having same diameter or lighty higher than of the hot
area.
Avoid overflows of liquid, therefore when boiling has happened, or
in any case when liquid is heated, reduce the heat supply.
Don't leave the heating elements on without receptacles on the
top or with void pots and pans.
Operating time [h]
0
10
5
5
4
3
2
2
2
1
1/6

Advertisement

Table of Contents
loading

This manual is also suitable for:

859991642420

Table of Contents