Panasonic GP-X Series User Manual page 65

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

6) Rotate the detected body to start detection.
Displayed value
Internal sampling
Timing indicator
In the sampling period, the peak point is determined first, and the
*
difference of the next minimum point is measured, displayed and output
as a peak-to-peak distance.
Ramco Innovations www.ramcoi.com
The peak-to-peak distance is displayed upon a trigger based on the minimum
point of the rotating body and judgment is output concerning the displayed value.
If the deviation is smaller than the hysteresis, no trigger is generated. Ex-
amine the settings.
POINT
Press the
Reference
the upper line) and measured value (on the lower line). For details, refer to
" Detection Mode" on page 27.
Rotation/eccentricity detection mode
Trigger point
Minimum point
0
ON
OFF
Start of measuring mode
key in the detection state to check the detected value (on
This point is not considered to be the minimum
point because it is within the hysteresis.
P1
Trigger point
Trigger
hysteresis
B1
Minimum point
Sampling period 1
Phone 800-280-6933 nsales@ramcoi.com
Distance between
P2 and B2 is
Distance between P1 and
displayed and output.
B1 is displayed and output.
P2
B2
Sampling period 2
59