3.3 Averaging Frequency Setting
Change the averaging frequency to obtain the best relationship between the
response time and variation in detection.
■ Relationship Between Averaging Frequency and Response Time
Change the averaging frequency to "1,024" times.
<Detection state>
Ramco Innovations www.ramcoi.com
If high-speed judgment is necessary, set a smaller averaging frequency.
to suppress any variation in detection.
POINT
Averaging
Response time (ms)
frequency
1
0.075
2
0.100
4
0.150
8
0.250
16
0.450
32
0.850
64
1.650
:Factory shipment setting
Setting example
Averaging frequency
setting mode
Press the
Averaging
Response time (ms)
frequency
128
256
512
1,024
2,048
4,096
102.450
8,192
204.850
16,384
409.650
The
Press
to select "AVE".
Press
key to turn off the indicator to return to the detection mode.
Phone 800-280-6933 nsales@ramcoi.com
3.250
6.450
12.850
25.650
51.250
key indicator lights up.
to select "1,024".