Panasonic GP-X Series User Manual page 126

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

Command for adjustment
Item
Scaling
Display
120
Ramco Innovations www.ramcoi.com
Controller
Command
Instruction character
address
string (m)
Loading
Writing
(n)
1)
0=
1st point of
two-point
scaling
1=
2nd point of
two-point
scaling
RSD
0
2=
Setting of
two scaling
points
3=
Scaling
selection
data
4=
Output
inverse
ON/OFF
X1_Y1 (1st
0=
point of two-
point scaling)
X2_Y2 (2nd
1=
point of two-
point scaling)
2=
X1_Y1 (One-
point scaling)
3=
X1_Y1_X2_Y2
(Two-point
scaling)
4=
Y1 (Teaching
of 1st point of
WSD
0
two-point
scaling)
5=
Y2 (Teaching
of 2nd point
of two-point
scaling)
6=
Y1 (Teaching
of one-point
scaling)
(Inverse
7n=
ON/OFF)
(Recovery of
9=
factory shipment
setting)
Outline
Load the current scaling data of displayed
measurement.
The detected distance and the corresponding
displayed value are sent back.
<Loading the setting of each scaling point>
% E E # R S D n m
m = 0 or 1
The response to the above command is:
% E E $ R S D n m
&
&
&
&
.
&
&
&
&
+
&
Detected distance value Analog voltage output value
m = 0 or 1,
C R
<Loading the setting of two scaling points (2 points batch)>
The response to
% E E # R S D n 2
is:
% E E $ R S D n 2
&
&
&
&
.
&
&
&
&
+
&
Detected distance value of 1st point
Analog voltage output value of 1st point
&
&
&
&
.
&
&
&
&
+
Detected distance value of 2nd point Analog voltage output value of 2nd point
C R
The response to
% E E # R S D n 3
is:
% E E $ R S D n m
m = 0: Factory shipment setting
m = 1: One-point scaling
m = 2: Two-point scaling
m = 3: Inverse
The response to
% E E # R S D n 4
is:
% E E $ R S D n m
m = 0: Inverse OFF
m = 1: Inverse ON
Enter the display scale setting for the
controller of the designated address.
There are seven types of setting
commands. You can use them according
to the purpose.
<One-point scaling>
%
E
E
#
W
S
D
n
2
&
Detected distance value
+ & & & . & & & &
Analog voltage output value
The response to the above command is:
% E E $ W S D n
C R
<Two-point scaling>
%
E
E
#
W
S
D
n
3
&
Detected distance value of 1st point
+
&
&
&
.
&
&
&
&
&
Analog voltage output value of 1st point Detected distance value of 2nd point
+ & & & . & & & &
Analog voltage output value of 2nd point
The response to the above command is:
% E E $ W S D n
C R
Phone 800-280-6933 nsales@ramcoi.com
Setting
example
C R
&
&
.
&
&
&
&
:Space
C R
&
&
.
&
&
&
&
&
&
&
.
&
&
&
&
:Space
C R
C R
C R
C R
&
&
&
.
&
&
&
&
C R
:Space
&
&
&
.
&
&
&
&
&
&
&
.
&
&
&
&
C R
Space