Ir Code Information - Zenith P50W38H Installation And Operating Manual

Plasma display panel
Table of Contents

Advertisement

IR Code Information

IR Code Information
How to Connect
How to Connect
G Connect your wired remote control to the Remote Control port on the Monitor.
Remote Control IR Code
Remote Control IR Code
G Output waveform
Single pulse, modulated with 37.917KHz signal at 455KHz
T
C
T1
G Configuration of frame
1st frame
Lead
Low
code
custom code
C0
C1 C2 C3 C4 C5 C6 C7 C0 C1 C2 C3 C4 C5 C6 C7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7
Repeat frame
Repeat code
G Lead code
G Repeat code
G Bit description
Bit "0"
0.56 ms
G Frame interval : Tf
The waveform is transmitted as long as a key is depressed.
Carrier frequency
F
= 1/T
CAR
C
Duty ratio = T1/T
High
custom code
9 ms
9 ms
2.25 ms
Bit "1"
1.12 ms
Tf
Tf=108ms @455KHz
= f
/12
OSC
= 1/3
C
Data code
T
f
4.5 ms
0.55 ms
0.56 ms
2.24 ms
Tf
IR Code Information
Data code