Trane S8B1A040M3PSCA/C Installation, Operation And Maintenance Manual page 64

Upflow/downflow/horizontal gas-fired, 1–stage and 2–stage induced draft furnaces with high efficiency motor
Table of Contents

Advertisement

T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g
DEFINITION
An error has occurred with the PS1, indica ng that the pressure
switch is closed when it should be open.
In most cases, the pressure switch is not the problem.
NOTE: Verify pressure switch wiring and tube rou ng
are correct.
correct, replace IFC
64
Verify wiring. If
NO
3.1 Fault Code
Cycle power OFF to the
furnace and remove
.
Orange wire from PS1.
,
Is con nuity (0 ohms)
YES
measured across PS1?
See Note #1
Note #1
OL = Open Switch
0 ohms = Closed Switch
Replace pressure
.
switch and verify
opera on
S8XB-SVX001-1C-EN

Advertisement

Table of Contents
loading

Table of Contents