For Ethernet units, if the following switch position are used the the IP address is set to a static one:
The static IP address settings chosen are: IP address: 192.168.0.2, subnet mask: 255.255.255.0
Once the IP address has changed the switch can be moved back to a known, normal, position.
Any other configuration of switches not shown here means the baud rate defaults to 9600.
RS485 unit address with switches 1 - 4 (0=off)
Note addresses have been started at 32 to avoid any possible conflict in reading data
4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
An internal connection change is required for changing from RS232 to RS485. For this ensure the unit is
switched off and the 12 cover screws are removed.
The jumper on LK1 on the microprocessor board needs to be set to the correct position in order to change
between RS232 and RS485 operation. The correct position is shown on the PCB.
Reset
BTN1 on the PCB is the push to RESET for the microprocessor
Issue 3.15
1
1
1
3
2
1
Address
0
0
0
0
0
0
1
0
0
1
0
0
0
1
0
0
1
0
1
1
0
1
1
0
0
0
1
0
0
1
1
0
1
1
0
1
0
1
1
0
1
1
1
1
1
1
1
1
RCU100 and RCU200 redundancy control units
0
Static IP
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
Page 9