Emc And Safety - PEAK COMMUNICATIONS RCU100 Installation And Operating Handbook

Table of Contents

Advertisement

The RCU100 and RCU200 units are 1 FOR 1 and 1 FOR 2 redundancy control units which are fully compatible
with the L500, IBU and IBD Up and Downconverter units from Peak Communications. By external cabling the
units can be configured to control either Up or Down converter units.
The RCU100 and RCU200 Redundancy control units are housed in 19 inch 1'U' high chassis, suitable for rack
mounting. They are 400 mm deep and may be fitted with rack slides if required.

EMC AND SAFETY

EMC
The RCU100 and RCU200 redundancy control units have been designed to comply with the following
standards;
Emissions
:
EN 55022 Class B; Limits and methods of measurement of radio interference characteristics
of Information Technology Equipment.
Immunity
:
EN 50082 Part 1; Generic immunity standard, part 1: Domestic, commercial and light
industrial environment.
The equipment must be operated with its lid on at all times. If it is necessary to remove the lid for routine
servicing or fault finding then it is essential that the lid is fitted back correctly before normal operation.
For the Alarm and Remote Control data interfaces all 'D' type connectors must have grounding fingers on the
plug shell to guarantee continuous shielding. The back-shells must comply with the requirements of VDE 0871
and FCC 20708, providing at least 40 dB of attenuation from 30 MHz to 1 GHz.
Connecting cables must be of the shielded
Operation of the equipment in a non standard manner will invalidate compliancy to these standards.
Safety
To ensure safety of operator the RCU100 and RCU200 redundancy control units have been designed to comply
with the following safety standard;
EN 60950
Safety of information technology equipment, including electrical business machines.
Before operation the user must ensure that the installation complies with the information given.
The equipment is designed to operate in a static 19 inch rack system conforming to IEC 297-2. Operation of the
equipment in transportable vehicles equipped with the means of providing a stable environment is permissible.
Operation of the equipment on board vehicles, ships or aircraft without means of environmental conditioning
will invalidate the safety compliancy; please contact the factory for further advice. Operation of the equipment in
an environment other than that stated in the specifications will also invalidate the safety compliancy. The
equipment must not be operated above 2000 metre altitude, extremes of temperature; excessive dust, moisture or
vibration; flammable gases; corrosive or explosive atmospheres.
Installation
The equipment is classified in EN 60950 as a pluggable equipment class A for connection to the mains supply,
as such it is provided with mains inlet cords suitable for use in the country of operation. In normal circumstances
they will be of an adequate length for installation in the rack. If a mains cord proves to be too short then any
Issue 3.15
INTRODUCTION
RCU100 and RCU200 redundancy control units
Page 2