neverdark CHALET-II Technical Documentation Manual

neverdark CHALET-II Technical Documentation Manual

Smart fireplace
Hide thumbs Also See for CHALET-II:

Advertisement

Quick Links

Neverdark CHALET-II (EX)
Smart fireplace
TECHNICAL DOCUMENTATION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHALET-II and is the answer not in the manual?

Questions and answers

Summary of Contents for neverdark CHALET-II

  • Page 1 Neverdark CHALET-II (EX) Smart fireplace TECHNICAL DOCUMENTATION...
  • Page 3: Table Of Contents

    CONTENT INTERFACES CONFIGURATION Standard configuration Available options THERMOBOXES INTERFACES General Fireplace DIMENSIONS Fireplace NICHE PREPARATION INSTALLATION Niche for fireplace Niche requirements Niche for Standard ARS Niche for Standard ARS (with fuel canister) Niche for Mini ARS INSTALLATION Laying of communications for Standard ARS Laying of communications for S-ARS (with fuel canister) Laying of communications for Mini ARS Connecting communications to ARS...
  • Page 4 ATTENTION! This document, together with the User Manual, is part of the device and is delivered together with the fireplace (hereinafter collectively referred to as "Instructions"). If one or both of these documents did not come with your fireplace, please contact the manufacturer before installing and/or using the fireplace.
  • Page 5: Configuration

    CONFIGURATION Standard configuration Smart fireplace Decorative elements: decorative stones, 1 pc ceramic firewood, fiber for glow Power cable: effect Euro Plug - WAGO (length: fireplace length + 0.1m) 1 set 1 set T-Handles Key for fuel line for mounting 1 pc 2 pc Micro USB cable Documentation...
  • Page 6: 05 | Available Options

    Available options You can choose any option, shown below. Glass Border Remote Control (one, two) code code GB (1, 2) Smart Home Custom Top сonnection (Glossy (black), module RAL Glossy, RAL Matte, Inox) code code CT (G, RG, RM, I) Enlarged Fuel Tank code...
  • Page 7: Thermoboxes

    THERMOBOXES You can also choose the Neverdark Thermobox for your fireplace. The Thermobox can withstand temperatures up to 200°C, allowing you to choose any material for lining the niche. Single-Sided Three-Sided code code Right Corner Room Divider code code Left Corner...
  • Page 8: Interfaces

    INTERFACES General Fireplace Communications АRS 07 | general...
  • Page 9: Fireplace

    Fireplace ventilation Tray for decorative grids elements Power cable 220V Burner RJ cable port USB extension cable port ARS power cable port Fuel drain connector (service only) Fuel line connector fireplace interface | 08...
  • Page 10: Ars

    Standard ARS Touch display Power button Fuel hose Micro USB connection (service only) USB extension cable port ARS power cable port Fuel line connector RJ cable port 09 | ARS interface...
  • Page 11 Mini ARS (up) Micro USB port (service only) Fuel hose Touch display connector Power button Magnetic frame USB extension cable port RJ cable port Fuel line ARS power cable connector port Mini ARS (down) Magnetic frame Touch display Fuel hose connector Micro USB port (service only)
  • Page 12: Dimensions

    DIMENSIONS Fireplace Standard range Length, Depth, Height, Weight, Model Code Chalet-II 700 + ARS C2-700 21.1 Chalet-II 950 + ARS C2-950 Chalet-II 1200 + ARS C2-1200 1200 11 | fireplace dimensions...
  • Page 13: Ars

    Standard ARS Mini ARS (Up and Down) ARS dimensions | 12...
  • Page 14: Niche Preparation

    NICHE PREPARATION Niche for fireplace Communications Clearance 6 Clearance 6 40 mm² Air supply 1000 mm² ATTENTION! For min 20 correct operation of the smart fireplace, it must be installed 100% horizontally according to the level! Clearance 6 min 20 13 | fireplace niche dimensions...
  • Page 15: Niche Requirements | 14

    Min 500 mm to flammable Non heat-resistant material + objects from any closed Neverdark Thermobox side of the niche. ATTENTION! For safe and correct operation of the fireplace it is compulsory to provide an air supply opening (minimum 100 cm²) into the lower part of the niche.
  • Page 16: 15 | Niche For Standard Ars

    Niche for Standard ARS To correctly mark the mounting holes in the wall, temporarily insert the ARS Opening for communications min 120 15 | niche for Standard ARS...
  • Page 17: Niche For Standard Ars (With Fuel Canister)

    Niche for Standard ARS (with fuel canister) To correctly mark the mounting holes in the wall, temporarily insert the ARS Opening for communications niche for Standard ARS | 16...
  • Page 18: 17 | Niche For Mini Ars

    Niche for Mini ARS (Up and Down) To correctly mark the mounting holes in the wall, temporarily insert the ARS 17 | niche for Mini ARS...
  • Page 19: Installation

    INSTALLATION Laying of communications for Standard ARS laying of communications | 18...
  • Page 20: Laying Of Communications For Standard Ars

    Laying of communications for Standard ARS (with fuel canister) 19 | laying of communications...
  • Page 21: Laying Of Communications For Mini Ars

    Laying of communications for Mini ARS (Up and Down) laying of communications | 20...
  • Page 22: Connecting Communications To Ars

    Connecting communications to ARS Standard ARS Fireplace Fuel drainer Key for fuel line RJ cable Fuel line ARS power cable USB extension cable Mini ARS Fireplace Key for fuel line RJ cable Fuel line ARS power cable USB extension cable ATTENTION! 220V cable connection must be carried out by a qualified electrician.
  • Page 23: Installation Standard Ars | 22

    Installation Standard ARS Screw 6 pc, 3x20 installation Standard ARS | 22...
  • Page 24: Installation Standard Ars (With Fuel Canister)

    Installation Standard ARS (with fuel canister) Screw 6 pc, 3x20 23 | installation Standard ARS...
  • Page 25: Installation Mini Ars | 24

    Installation Mini ARS (Up and Down) Screw 4 pc, 3x20 Magnetize installation Mini ARS | 24...
  • Page 26: Connecting Communications To Fireplace

    Connecting communications to fireplace Standard ARS Fireplace Fuel drainer RJ cable Fuel line Key for fuel line ARS power cable USB extension cable Mini ARS Fireplace RJ cable Fuel line Key for fuel line ARS power cable USB extension cable ATTENTION! 220V cable connection must be carried out by a qualified electrician.
  • Page 27: Installation Fireplace

    Installation fireplace ATTENTION! 220V cable connection must be carried out by a qualified electrician. T-Handles for mounting Plug 220V (option 1) Cable 220V 3x2.5mm (option 2) installation fireplace | 26...
  • Page 28: Features

    FEATURES Technical data Fireplace model Parameters Chalet-II (Ex) Chalet-II (Ex) Chalet-II (Ex) 1200 Tank volume, l System volume, l Consumption, I/h 0,4 | 1,0 0,6 | 1,2 0,8 | 1,7 (min | max) Average consumption, I/h (min | max) Burning time, h...
  • Page 29: Warnings

    fireplace resulting from exposure to high temperatures. ATTENTION! For the safe use of the Neverdark smart fireplace, follow the rules: Keep away from children; Ensure that the wall/table/floor on which you place the appliance can support its weight;...
  • Page 32 NEVERDARK LLC 11 Kopernika St. Kyiv, Ukraine neverdark.one...

Table of Contents