Windbit
⚫
When performing electrical operations, comply with local regulations and rules. The relevant staff must have
the corresponding qualifications.
⚫
Check carefully whether there are potential dangers in the work area, such as whether the ground is wet.
⚫
Before installation, you need to know the location of the emergency power switch in the room. When an
accident occurs, the power switch must be turned off.
⚫
Check carefully before turning off the power.
⚫
Do not place the device in moist places and prevent liquid from entering the device.
⚫
It is not recommended to use the AP working ground together with the ground device of electrical equipment
or lightning protection ground device, and separate them as far as possible.
⚫
Keep the device far away from wireless transmitters, radar transmitters, high-frequency high-current devices,
microwave ovens and other high-power wireless devices.
2.1.4
Storage Safety
To ensure the normal operating of the device, see the storage temperature/humidity requirements in the
specifications for the storage environment of the device.
Caution
If the storage time exceeds 18 months, the device needs to be powered on and run for 24 hours without
interruption for device activation.
2.2
Installation Environment Requirements
The device must be used indoors to ensure normal operating and prolong its service life.
The installation site should meet the following requirements.
2.2.1
Load-bearing Requirements
Evaluate the floor load-bearing requirements according to the actual weight of the installed device and its
accessories (such as mounting plate and power supplies), and ensure that the load-bearing capacity of the
installation site meets the requirements.
2.2.2
Ventilation Requirements
Reserve the position for vent to ensure heat dissipation. After connecting all cables, arrange them into bundles
or place them on the cable distribution frame to avoid blocking the air inlet.
Space Requirements
2.2.3
To facilitate heat dissipation and maintenance of the device, do not install the device against the wall. Leave a
certain space (not less than 0.4 m) for the left and right panels to facilitate heat dissipation.
WAP840-Iax Access Points
Access Point Hardware Installation and Reference Guide
18