PRESSURE TESTING

(Have a trained pool professional perform all pressure tests). Before pressure testing,
make the following safety checks:
1. Check all clamps, bolts, lids, and system accessories prior to testing.
2. Release all air in system before testing.
3. Tighten trap lid to 4.1kg-m torque for testing.
4. Water pressure for test must be less than 170kPa (25 PSI)
5. Water tempertaure for test must be less than 38°C
6. Limit test to 24 hours. After test, visually check system to be sure it is ready for
operation. Remove trap lid and retighten hand tight only.
Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves,
debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let
it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor
from heat damage during operation.
Only qualified, licensed personnel should install pump. The electrical installation shall be in accordance
with the national wiring rules (AS/NZS 3000) for class I, IP55 rated products. Refer to page 10 for Electrical
Installation.imit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Remove trap lid and retighten hand tight only.