AEC/Appllcatlon Engineering
Pressure Gauge -
Discharge Port
I. High reading indicates:
fluid has high viscosity and small and/or long discharge line
partially closed gate valve
plugged filter
line partially plugged from buildup
fluid in pipe not up to temperature
fluid in pipe underwent a chemical reaction and solidified
relief valve set too high
2. Low reading indicates:
relief valve is set too high
relief valve poppet is not seating properly
bypass around the pump is partially open
too much extra clearance
worn pump
3. Fluttering, jumping, or erratic readings:
cavitation
fluid coming to the pump in slugs
air leak in the suction line
vibrating from misalignment or mechanical problems
Detennlnlng Pump Problems
A.
Pump does not pump.
I . Pump lost priming - possible air leak, low
tank
levels, stuck foot valve.
2. Suction lift is too high.
3. Pump is rotating in the wrong direction.
4. The motor is not running at the proper speed.
5. Suction and discharge valves are not open.
6. Clogged strainer.
7. Open bypass valve, relief valve is set too low, relief valve poppet stuck open.
Page 64
TOH TrueTemp"' Serles Hot 011 Temperature Control Units