AEC TrueTemp Series Operation And Installation Manual page 11

Toh hot oil temperature control unit
Hide thumbs Also See for TrueTemp Series:
Table of Contents

Advertisement

AEC/Appllcatlon Engineering
Maintains a constant flow of fluid through the heater tank to prevent damage to the heating
elements and fluid
Factory pre-set to maintain the system pressure specified by the customer- must not be
tampered with in any way
Pressure Switch
Built into each unit
Guards against heater damage
Prevents the heater elements from being energized unless the pump is running and fluid is
in the system
Factory set; no field adjustments needed - must not be tampered with
Safety Thermostat
Protects against thermal runaway
Shuts down the heater outputs, sounds the audible alarm, and lights the alarm indicator if an
over temperature condition exists
Pump continues to run, pumping fluid through the system to prevent heater damage
Automatic reset design resets the thermostat as the unit cools
All heater controller functions lock out until you reset main power
Note:
Always have a qualified maintenance technician determine and correct the cause of an
over temperature fault before you resume operation
Electrical Components
NEMA 1 standard electrical enclosure
IEC motor starters
Full unit fusing - pump motor, heater, primary side transformer
High temperature heater cutout
High temperature audible and visual alarm, activated by the safety thermostat
Pressure switch shuts down heater for low pressure
Mercury heater contactors
Pump motor and immersion heater operate on three-phase, 50/60 cycle nominal voltage
with control circuit at I l 5V single phase
Single phase machine tool transformer with primary fuse protection and grounded
secondary supplies control circuit voltage
Electrical panel complies with NEC provisions