Standard Features
•
One-person startup operation
•
Sides and back lift off for easy access without tools
•
Shrouded fluid level sight gauge up front
•
Fork lift rails on base
•
Y-type filter/strainer in RETURN piping
•
Fluid FILL and VENT outlets on top of the unit
•
Most piping connections can be made at the rear of the unit
Heaters
•
Three-phase immersion heater design
•
Low watt-density steel sheath
•
Patented two-pass heater tube design (TDH5 only); maintains an optimum balance of fluid
velocity versus watt density with maximum turbulence for excellent heat transfer and
minimal pressure drop
•
6 kW, 12 kW, 18 kW, 24 kW, 30 kW, 36 kW, 42 kW, and 48 kW units available
•
Single heater design for units up to 24 kW, dual heaters in series for units up to 48 kW
Pump
•
Suited for use with a selection of AEC-recornrnended commercially-available heat transfer
fluids; AEC, Inc. recommends AEC True Therm™ heat transfer fluid for best results
•
Only two internal moving parts
•
Specially designed seal gives years of trouble-free service, even at high temperatures
•
Only routine maintenance required is periodic greasing
•
Positive displacement mechanical seal gear pump
•
18, 24, and 50 gpm flow
•
30 or 50 psi pressure to process available
•
1, 1 Y,, 2 hp (HL), and 3 hp (KK) pumps available
•
Pump reverse feature lets you return fluid to the reservoir from the mold and process lines
•
A bypass valve regulates discharge pressure
Ful-Flo Valve Bypass
•
•
•
Prevents excessive pressure ifthe DELIVERY line is obstructed; if an obstruction occurs, the
•
Ful-Flo valve bypass opens to divert fluid to the RETURN line
Page 10
TOH TrueTemp"' Series Hot Oil Temperature Control Units