3.19    Main IC's key test point (Reset circuit) 
  12V will charge to C957 (Capacitance is short circuit in the period of charge) when 
system is power on.Q905's B and E is in same level. Dynatron is cut‐off. C pole is in 
low level. When C957 is full (Capacitance is same to open circuit), Q805's B is 0.7v or 
more small than E's level. Dynatron is break‐over. C pole will output high voltage level. 
Main  IC  request  the  RESET  time  is  more  than  10S.  Q906  is  designed  to  prevent 
system reset in standby. If there has no Q906 (RESET signal will be plugged to high 
level in normal work or even in standby), 24V will drop in standby and Q905's C will 
follow it, so the system will reset. 
RESET signal 
                      Power on reset                                                                Power off reset 
 
The  C  pole  of  Q905  is 
RESET test point. 