MHL  detect  control  circuit  as  follow.  MHL_DET  signal  will  be  set  to  high  level  by 
peripheral  equipment  when  MHL  peripheral  equipment's  line  is  connect  to  P801. 
MHL signal is inputted to Main IC (U104) directly, and is used for Main IC to detect 
and  estimate.  Otherwise  when  MHL  is  in  high  level,  Q800  is  break‐over,  Q805  is 
cut‐off.  So  G  of  Q806  is  plugged  up  and  Q806  is  cut‐off.  Then  normal  HDMI's  HPD 
signal will be cut‐off. MHL_DET is in low level when MHL peripheral equipments are 
not  connected  in.Q800  is  cut‐off.  Q805  is  break‐over.  G  of  Q806  is  dragged  to  low 
level.Q806 is break‐over. B of Q803 will be dragged to low level and cut‐off because 
of Q804 is break‐over. Then HPD is plugged to high level by OPWR5V,and is detected 
as Normal HDMI to input. 
 