Advertisement

Quick Links

Product Manual
Models:
RSS2010E
www.raditeq.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Essential RSS2010E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for raditeq Essential RSS2010E

  • Page 1 Product Manual Models: RSS2010E www.raditeq.com...
  • Page 2 For your convenience, a Quick Start Guide has been added to this product. This Quick Start Guide contains the basic start-up steps and the safety warnings. Please keep the Quick Start Guide (and this regular manual) close at hand when you operate your new Raditeq product(s).
  • Page 3: Table Of Contents

    Program the correction file into the probe Enabling the user correction file RadiSense® specifications RadiSense® general specifications Warranty Conditions Declaration of Conformity Page 3 of This product manual is subject to change without notice Page 3 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 4: Warnings & Precautions

    This product contains no hazardous substances as described in the RoHS Directive (2011/65/EU). This product contains embedded software, which is field upgradeable from the RadiCentre® using the USB-A connection port on the backside panel of the RadiCentre®. For more information about updating your Raditeq plug-in card, please read the RadiCentre® manual.
  • Page 5 Only use optic fibre cables supplied by Raditeq, or one of her official Resellers. Using alternative cables will result in (burn) damage to the probe and fibres. the use of 3rd party cables also results in a void of warranty.
  • Page 6: Laser - Safety Measures

    A visual ‘LASER ON’ indicator LED will light up when the laser is activated. This LED on the front panel of the RadiCentre® system serves as a reminder to the operator that one or more lasers are switched on. This product manual is subject to change without notice Page 6 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 7 RadiCentre® plug-in cards and modules. RadiMation® Software RadiMation ® is the EMC software package from Raditeq used for remote control and automated testing of the RadiCentre® plug-in cards and modules and is sold separately.
  • Page 8: The Radisense® Series

    RSS2010E The RadiSense® Series Raditeq brings over 30 years of expertise in the field of EMC. In addition to designing both large and small EMC/ RF projects for clients in automotive, military, and space industries, Raditeq offers considerable proficiency in anechoic chamber calibrations and conducting EMC immunity and emission tests.
  • Page 9: Radisense® System

    (if an ISO/IEC 17025 accredited calibration certification was ordered). • Hardcopy of the Quick Start Guide. • Lint free cleaning wipes This product manual is subject to change without notice Page 9 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 10: Fibre Optic Cables

    To ensure the safe and correct operation of the sensor, only use the RadiSense® with the original supplied or ordered fibres optic cables. Do not use other fibres optic cables than those supplied by Raditeq. Fibre optic extension cables with different lengths up to 100 meters are available on request. Note that for the probe to correctly function the fibre optic cable can be extented by a maximum of two coupling sets.
  • Page 11: Laser - Safety Measures

    A visual ‘LASER ON’ indicator LED will light up when the laser is activated. This LED on the front panel of the RadiCentre® system serves as a reminder to the operator that one or more lasers are switched on. This product manual is subject to change without notice Page 11 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 12 (if the ‘Start’ button is being pressed). To interrupt the activation process, all you must do is release the ‘Start’ button. This product manual is subject to change without notice Page 12 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 13: Fibre Handling And Maintenance

    To ensure the Fibre optic cable remains in its ideal state make sure that the ST optic fibre connectors (on the RadiSense) and the bidi link (on the LPS2001B plug-in Card) are cleaned periodically. This product manual is subject to change without notice Page 13 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 14: Fibre Conditions

    Fibre conditions Use the examples and instructions in the following figure as a guideline for further fibre maintenance. If you have doubts about the condition of the fibre optic cables, please contact your local reseller or Raditeq for assistance and/or advise.
  • Page 15: Probe Stand

    M4 hole and a UNC 1/4 inch hole. This product manual is subject to change without notice Page 15 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 16: Mounting Angle Usage For Radisense® Probe

    This product manual is subject to change without notice Page 16 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 17: Installation Into The Radicentre

    RSS2010E Installation into the RadiCentre Please follow the instructions below on how to install the Raditeq plug-in card into the RadiCentre® correctly. NOTE: before installing and inserting a new plug-in card make sure that the RadiCentre® is turned OFF. Step 1 Choose an empty slot in the RadiCentre®...
  • Page 18: Connection Plugs

    To meet the laser safety precaution, enter the laser code in the ‘LASER Code’ screen and press ‘OK’ for confirmation. The standard/default Laser code is 3447 This product manual is subject to change without notice Page 18 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 19: Software Configuration

    To control the RadiSense from a computer, one can use either custom made software or the RadiMation® EMC software package from Raditeq, which can be downloaded from the Raditeq website. If the RadiSense® is operated manually, this chapter can be skipped.
  • Page 20: How To Connect The Radisense® To The Radicentre

    When the correct slot number is chosen, continue to set the communication of the RadiSense® by clicking ‘Communication tab’ (next page). This product manual is subject to change without notice Page 20 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 21: Setup The Communication Of The Radisense® To The Radicentre

    • • VISA When these steps are performed continue to the next steps for checking the communication of the RadiSense®. This product manual is subject to change without notice Page 21 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 22: How To Check Whether The Radisense® Is Properly Connected To Radimation

    It is also advised to visit the RadiMation® Wiki page and the FAQ section, which can be found at: https://wiki.radimation.com RadiMation® software can be downloaded at: https://www.raditeq.com/emc-test-software/radimation-download This product manual is subject to change without notice Page 22 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 23: Using The Radisense® With The Radicentre

    For maximum accuracy, it is recommended to re-zero the probe whenever the probe temperature changes by more than 5 This product manual is subject to change without notice Page 23 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 24: Setting The Correct Measurement Frequency

    Please note, a lower filter setting will increase measurement speed at the cost of increased noise levels. On the other side, a higher filter setting will reduce measurement speed while reducing the noise. This product manual is subject to change without notice Page 24 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 25: Radisense® 10E User Correction Calibration Data

    The RadiSense® 10 probe can store up to 200 “user correction factor” points. For manual uploading of the user correction data please refer to the white paper available on www.raditeq.com This product manual is subject to change without notice Page 25 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 26: Create And Upload User Correction With Radimation

    After selecting the new correction file the following screen shall be presented. To add the required X, Y and Z correction column press the ‘Columns/Units’ button shown on this screen. This product manual is subject to change without notice Page 26 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 27 After filling in this data into the correction file, this could for example look like the following (typical RadiSense® 10 frequency response correction data). This product manual is subject to change without notice Page 27 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 28: Program The Correction File Into The Probe

    This will enable the usage of the user calibration table during initialisation of the RadiSense® 10 when starting a test. This product manual is subject to change without notice Page 28 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 29: Radisense® Specifications

    10 – 90% (non-condensing) Warranty 3 years warranty on Hardware 1 year warranty on Calibration Certificate (see warranty condtions for more information) This product manual is subject to change without notice Page 29 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 30 4) Probe is delivered with 2.5 m fixed + 10 m extension fiber and FC/ST in-line coupling set as a standard. Additional fiber lengths are sold separately Three years warranty will be granted only after you register the product at www.raditeq.com. Without registration, a 1 year warranty period applies.
  • Page 31: Warranty Conditions

    Warranty Conditions Raditeq B.V. offers a standard warranty term of three (3) years on their products, calculated from the shipping date, under the condition that the product is registered on www.raditeq.com. For registration of the product, the customer should provide the product model, serial number and the responsible reseller (if applicable).
  • Page 32 Date of issue: Publish Date: 08/03/2024 Place of issue: Woerden, The Netherlands Authorized by: P.W.J. Dijkstra Title of authority: Director This product manual is subject to change without notice Page 32 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 33: Declaration Of Conformity

    Vijzelmolenlaan 3 | 3447 GX Woerden | The Netherlands Place of issue: Woerden, The Netherlands Date of Issue: 01/03/2023 Name: P.W.J. Dijkstra Function: Director This product manual is subject to change without notice Page 33 of 34 Copyright © 2008 - 2024 Raditeq B.V.
  • Page 34 Raditeq B.V. | Vijzelmolenlaan 3 | 3447GX Woerden | The Netherlands Raditeq B.V. | Vijzelmolenlaan 3 | 3447GX Woerden | The Netherlands www.raditeq.com | T:+31 348 200 100 www.raditeq.com | T:+31 348 200 100...

This manual is also suitable for:

Essential lps2001b

Table of Contents