raditeq RadiSense Pro Series Product Manual

Electric field probe

Advertisement

Quick Links

Product Manual
RadiSense
®
Electric Field Probe
Models:
RSS2010I | RSS2010S
| RSS2010M
www.raditeq.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RadiSense Pro Series and is the answer not in the manual?

Questions and answers

Summary of Contents for raditeq RadiSense Pro Series

  • Page 1 Product Manual RadiSense ® Electric Field Probe Models: RSS2010I | RSS2010S | RSS2010M www.raditeq.com...
  • Page 2: Supplier Information

    For all specifications of this specific product, please refer to the data sheet of the product which can be found at www.raditeq.com Please keep this manual close at hand when you operate your new Raditeq product(s). Please contact your local reseller if you have any questions. Supplier Information Raditeq B.V.
  • Page 3: Table Of Contents

    Program the correction file into the probe Enabling the user correction file Warranty Conditions Page 3 of This product manual is subject to change without notice Page 3 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 4: Warnings & Precautions

    Using this product with any other mainframe can cause harm and will void warranty. To make Raditeq’s product as safe as possible, all devices fitted inside a RadiCentre® must comply to the safety interlock system of the RadiCentre®. all Raditeq Plug-in cards are designed to work with the interlock fitted on all RadiCentre® systems.
  • Page 5 Make sure that the fibre optic cables are installed correctly before activating the system. Do not activate the system if the fibre optic cables show any sign of damage or tampering. This product manual is subject to change without notice Page 5 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 6 RadiCentre® plug-in cards and modules. RadiMation® Software RadiMation ® is the EMC software package from Raditeq used for remote control and automated testing of the RadiCentre® plug-in cards and modules and is sold separately.
  • Page 7: The Radisense® Series

    E-field readings without the need of additional calculations . Corrections will be applied inside the probe for each individual axis. This product manual is subject to change without notice Page 7 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 8: Radisense® Models

    (if an ISO/IEC 17025 accredited calibration certification was ordered). • Hardcopy of the Quick Start Guide. • Lint free cleaning wipes This product manual is subject to change without notice Page 8 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 9: Fibre Optic Cables

    To ensure the safe and correct operation of the sensor, only use the RadiSense® with the original supplied or ordered fibres optic cables. Do not use other fibres optic cables than those supplied by Raditeq. Fibre optic extension cables with different lengths up to 100 meters are available on request. Note that for the probe to correctly function the fibre optic cable can be extented by a maximum of two coupling sets.
  • Page 10: Laser - Safety Measures

    RadiCentre® system serves as a reminder to the operator that one or more lasers are switched on. This product manual is subject to change without notice Page 10 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 11 ‘Start’ button is being pressed). To interrupt the activation process, all you must do is release the ‘Start’ button. This product manual is subject to change without notice Page 11 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 12: Fibre Handling And Maintenance

    To ensure the Fibre optic cable remains in its ideal state make sure that the ST optic fibre connectors (on the RadiSense) and the bidi link (on the LPS2001B plug-in Card) are cleaned periodically. This product manual is subject to change without notice Page 12 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 13: Fibre Conditions

    Fibre conditions Use the examples and instructions in the following figure as a guideline for further fibre maintenance. If you have doubts about the condition of the fibre optic cables, please contact your local reseller or Raditeq for assistance and/or advise.
  • Page 14: Probe Stand

    M4 hole and a UNC 1/4 inch hole. This product manual is subject to change without notice Page 14 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 15 Please be noted that placing dielectric material in close proximity to the field sensor will influence the field and could cause measurement errors. This product manual is subject to change without notice Page 15 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 16: Installation

    When installed properly, the plug-in card should be recognized and shown automatically on the front screen of the RadiCentre® when turned ON. This product manual is subject to change without notice Page 16 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 17: Connection Plugs

    To meet the laser safety precaution, enter the laser code in the ‘LASER Code’ screen and press ‘OK’ for confirmation. The standard/default Laser code is 3447 This product manual is subject to change without notice Page 17 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 18: Software Configuration

    To control the RadiSense from a computer, one can use either custom made software or the RadiMation® EMC software package from Raditeq, which can be downloaded from the Raditeq website. If the RadiSense® is operated manually, this chapter can be skipped.
  • Page 19: How To Connect The Radisense® To The Radicentre

    When the correct slot number is chosen, continue to set the communication of the RadiSense® by clicking ‘Communication tab’ (next page). This product manual is subject to change without notice Page 19 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 20: How To Setup The Communication Of The Radisense® To The Radicentre

    When these steps are performed continue to the next steps for checking the communication of the RadiSense®. This product manual is subject to change without notice Page 20 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 21: How To Check Whether The Radisense® Is Properly Connected To Radimation

    It is also advised to visit the RadiMation® Wiki page and the FAQ section, which can be found at: https://wiki.radimation.com RadiMation® software can be downloaded at: https://www.raditeq.com/emc-test-software/radimation-download This product manual is subject to change without notice Page 21 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 22: Using The Radisense

    For maximum accuracy, it is recommended to re-zero the probe whenever the probe temperature changes by more than 5 This product manual is subject to change without notice Page 22 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 23 5 = 64 times average 11 = 4096 times averaging 6 = 128 times average 12 = 8192 times averaging This product manual is subject to change without notice Page 23 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 24: Radisense® 10 User Correction Calibration Data

    For manual uploading of the user correction data please refer to the white paper available on www.raditeq.com This product manual is subject to change without notice Page 24 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 25: Create And Upload User Correction With Radimation

    After selecting the new correction file the following screen shall be presented. To add the required X, Y and Z correction column press the ‘Columns/Units’ button shown on this screen. This product manual is subject to change without notice Page 25 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 26 After filling in this data into the correction file, this could for example look like the following (typical RadiSense® 10 frequency response correction data). This product manual is subject to change without notice Page 26 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 27: Program The Correction File Into The Probe

    This will enable the usage of the user calibration table during initialisation of the RadiSense® 10 when starting a test. This product manual is subject to change without notice Page 27 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 28: Warranty Conditions

    Warranty Conditions Raditeq B.V. offers a standard warranty term of three (3) years on their products, calculated from the shipping date, under the condition that the product is registered on www.raditeq.com. For registration of the product, the customer should provide the product model, serial number and the responsible reseller (if applicable).
  • Page 29: Eu Declaration Of Conformity

    Publish Date: 23/01/2025 Place of issue: Woerden, The Netherlands Authorized by: P.W.J. Dijkstra Title of authority: Director This product manual is subject to change without notice Page 29 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 30: Declaration Of Conformity

    Vijzelmolenlaan 3 | 3447 GX Woerden | The Netherlands Place of issue: Woerden, The Netherlands Date of Issue: 01/03/2023 Name: P.W.J. Dijkstra Function: Director This product manual is subject to change without notice Page 30 of 31 Copyright © 2008 - 2023 Raditeq B.V. | Version - 10...
  • Page 31 Raditeq B.V. | Vijzelmolenlaan 3 | 3447GX Woerden | The Netherlands Raditeq B.V. | Vijzelmolenlaan 3 | 3447GX Woerden | The Netherlands www.raditeq.com | T:+31 348 200 100 www.raditeq.com | T:+31 348 200 100...