Input Rectifier Test - Lincoln Electric OPTIMARC CV500 Service Manual

Table of Contents

Advertisement

SVM7007                                                          TROUBLESHOOTING AND REPAIR                                                                    E‐11 
 
Service  and  repair  should  be  performed  only  by  Lincoln  Electric  factory  trained  personnel.  Unauthorized  repairs 
performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory 
warranty.  For  your  safety  and  to  avoid  electrical  shock,  please  observe  all  safety  notes  and  precautions  detailed 
throughout this manual. 
 
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact 
the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. CALL 400 820 9755 
 
DESCRIPTION 
This test will help determine if the Input Rectifier is functioning correctly. 
 
MATERIALS NEEDED 
 
8mm
Wrench 
Multimeter 
Wiring Diagram 
 
PROCEDURE 
1. Remove the input power to the OPITIMARC® CV/CC500 machine. 
2. Perform the Case Cover Removal Procedure, remove the case top. 
    WARNING 
3. Locate the Input Rectifier. See figure E.6. Using an 8mm wrench, remove output leads 207# and 209# from the Input 
Rectifier. 
4. Perform the diode checks per Table E.1. If the measured value deviates greatly from the expected value, the Input 
Rectifier may be faulty. Perform the Input Rectifier Removal and replace it. 
 
Note: The Input Switch and Switchboard should be checked before replace the Input Rectifier. 
 
INPUT RECTIFIER TEST 
 
WARNING 
ELECTRIC SHOCK can kill! 
Wait until the Switchboard is fully discharged.
 
®