Check that the exterior of the cardboard delivery packaging is intact and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address.
1 x Wrist blood pressure monitor with cuff
1 x Instructions for use
1 x Quick Start Guide
1 x Storage box
2 x 1.5V AAA batteries LR03
The following symbols are used on the device, in these instructions for use, on the packaging and on the type plate for the device:
Warning instruction indicating a risk of injury or damage to health | |
Safety note indicating possible damage to the device/accessory | |
Product information Note on important information | |
Observe the instructions Read the instructions before starting work and/or operating devices or machines | |
Isolation of applied parts Type BF Galvanically isolated application part (F stands for "floating"); meets the requirements for leakage currents for type B | |
Direct current The device is suitable for use with direct current only | |
Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE | |
Do not dispose of batteries containing hazardous substances with household waste | |
Dispose of packaging in an environmentally friendly manner | |
Manufacturer | |
Temperature limit The temperature limit values to which the medical device can safely be exposed are indicated. | |
Humidity, limit Indicates the humidity range to which the medical device can safely be exposed. | |
Atmospheric pressure, limit Indicates the range of atmospheric pressures to which the medical device can be safely exposed | |
IP22 | IP class Device protected against foreign objects ≥ 12.5 mm and against water dripping at an angle |
SN | Serial number |
CE labelling This product satisfies the requirements of the applicable European and national directives. |
The blood pressure monitor is intended for the fully automatic, non-invasive measurement of arterial blood pressure and pulse values on the wrist.
It is designed for self-measurement by adults in the home environment and is suitable for users whose wrist circumference is within the range printed on the cuff.
The user can record their blood pressure and pulse values quickly and easily using the device. The recorded values are classified according to internationally applicable guidelines and evaluated graphically. Furthermore, the device can detect any irregular heart beats that occur during measurement and inform the user via a symbol in the display. The device saves the recorded measurements and can also output average values of previous measurements.
The recorded data can provide healthcare service providers with support during the diagnosis and treatment of blood pressure problems, and therefore plays a part in the long-term monitoring of the user's health.
Information on the display:
If the battery change symbol is flashing and appears, no further measurements are possible and you must replace all batteries. Once the batteries have been removed from the device, the date and time must be set again. Any saved measured values are retained.
You must make sure that the device has the correct settings before use in order to be able to make full use of all functions. Only by doing so can your measurements with associated date and time be saved and accessed later by you.
There are two different ways to access the menu from which you can adjust the settings:
In this menu you can adjust the following settings in succession:
It is essential to set the date and time. Otherwise, you will not be able to save your measured values correctly with a date and time and access them again later.
Hour format
The hour format now flashes on the display.
Date
The year flashes on the display.
The month flashes on the display.
The day flashes on the display.
If the hour format is set as , the day/month display sequence is reversed.
Time
The hours flash on the display.
The minutes flash on the display.
Bluetooth®
The Bluetooth® symbol is shown in the display.
Bluetooth® transfers will reduce the battery life.
You have 2 memories, each with 60 memory spaces, to enable the separate storage of measurements for 2 different people.
To select the corresponding user memory, press the M1 memory button (for user ) or M2 (for user ) on the switched-off device. Confirm your selection by pressing the START/STOP button .
As described above, attach the cuff and adopt the posture in which you want to perform the measurement.
The blood pressure monitor will begin the measurement automatically after 5 seconds.
The cuff automatically inflates. The measurement itself is taken during the inflation phase. As soon as a pulse is found, the pulse symbol is displayed.
You can cancel the measurement at any time by pressing the START/STOP button .
The World Health Organization (WHO) has defined the internationally recognised classification for the evaluation of measured blood pressure values listed in the table below:
Measured blood pressure value range | Classification | Colour of the risk indicator | |
Systole (in mmHg) | Diastole (in mmHg) | ||
≥ 180 | ≥ 110 | High blood pressure stage 3 (severe) | Red |
160 – 179 | 100 – 109 | High blood pressure stage 2 (moderate) | Orange |
140 – 159 | 90 – 99 | High blood pressure stage 1 (mild) | Yellow |
130 – 139 | 85 – 89 | High normal | Green |
120 – 129 | 80 – 84 | Normal | Green |
< 120 | < 80 | Optimal | Green |
Source: WHO, 1999 (World Health Organization)
The risk indicator (the arrow in the display and the associated scale on the device) shows which category the recorded blood pressure values fall into. If the measured values are in two different classifications (e.g. systole in the high normal category and diastole in the normal category), the risk indicator then always shows you the higher category – "high normal" in the example described.
Please be aware that these standard values can only serve as a general guideline, as the individual blood pressure varies in different people and different age groups, etc. Furthermore, it must be noted that measurements taken yourself while at home are generally lower than those that are taken by the doctor. For this reason, it is important that you regularly consult your doctor for advice. Only they are able to give you your personal target values for controlled blood pressure – in particular if you receive medicinal therapy.
This device can identify any cardiac rhythm disturbances as part of the analysis of your recorded pulse signal during blood pressure measurement. In this case, after the measurement, the device will indicate any irregularities in your pulse by displaying the symbol in the display. This can be an indicator for arrhythmia. Arrhythmia is an illness in which the heart rhythm is abnormal because of flaws in the bioelectrical system that regulates the heartbeat. The symptoms (skipped or premature heart beats, pulse being slow or too fast) can be caused by factors such as heart disease, age, physical disposition, excess alcohol and tobacco, stress or lack of sleep. If the symbol appears on the display after the measurement, the measurement must be repeated as the measurement accuracy may be impaired. To assess your blood pressure, only use the results that have been recorded without corresponding irregularities in your pulse. If the symbol appears frequently, please consult your doctor. Only they can establish the existence of an arrhythmia during a checkup, using their means of diagnosis.
User memory
The results of every successful measurement are stored together with the date and time. The oldest measurement is overwritten in the event of more than 60 measurements.
If you press the memory button M1 or M2 in the meantime, the transfer is cancelled. The symbol is no longer shown.
Average values
A is displayed.
The average value of all saved measured values in this user memory is displayed.
Individual measured values
You can exit the menu at any time by pressing the START/STOP button .
Delete the measured values
appears on the display. All the values in the selected user memory have now been deleted.
It is also possible to transfer the measured values saved on the device to your smartphone via Bluetooth®. You will need the " beurer HealthM anager" app for this. This is available in the Apple App Store and from Google Play.
System requirements for the app "beurer Health Manager":
Proceed as follows to transfer values:
If Bluetooth® is activated in the settings menu, the data is transferred automatically after the measurement. The symbol appears in the top left of the display (see chapter „Initial use", section "Bluetooth®").
When connecting for the first time, a randomly-generated six-digit PIN code is displayed on device, and at the same time an input field appears on the smartphone in which you must enter this six-digit PIN code. After successfully entering the code, the device will be connected to your smartphone.
Step 1: BC 54
Activate Bluetooth ® on your device (see chapter „Initial use", section "Bluetooth ® ").
Step 2: " beurer Health Manager" app
In the " beurer Health Manager" app, add the BC 54 under "Settings/My devices".
Step 3: BC 54
Take a measurement.
Step 4: BC 54:
Data transfer immediately following measurements.
Step 4: BC 54:
Data transfer at a later point:
The " beurer HealthM anager" app must be active to allow data transfer.
If your smartphone has a protective cover, remove this to ensure that there is no interference during the transfer. Begin the data transfer in the " beurer HealthM anager" app.
We would explicitly draw attention to the fact that the software to hand is not a medical product in accordance with EU Directive 93/42/EEC.
The values displayed are purely for visualisation purposes and must not be used as a basis for therapeutic treatments. The software is not part of a diagnostic-medical system.
Error message | Possible cause | Solution |
Unable to record a pulse. | Please wait one minute and repeat the measurement. Ensure that you do not speak or move during the measurement. | |
You have moved or spoken during the measurement. | ||
The cuff was not attached correctly. | Please observe the notes in chapter "Usage" under the section "Attaching the cuff". During a new measurement, check whether the cuff can now be inflated properly. | |
An error occurred during measurement. | Please wait one minute and repeat the measurement. Ensure that you do not speak or move during the measurement. | |
The inflation pressure is higher than 300 mmHg or the measured blood pressure is outside the measuring range. | ||
The batteries are almost empty. | Insert new batteries into the device. | |
The data could not be sent via Bluetooth®. | Proceed as described in chapter „Usage" under the section „Transfer via Bluetooth®" into the manual memory mode and try to restart the data transfer. | |
A device error has occurred. | Please repeat the measurement after a pause of one minute. |
If the problems persist despite the proposed corrective actions, please contact customer service.
Model no. | BC 54 |
Measurement | Oscillometric, non-invasive blood method pressure measurement on the wrist |
Measurement range | Cuff pressure 0-299 mmHg, Systolic 60-230 mmHg, Diastolic 40-130 mmHg, Pulse 40-199 beats/minute |
Display accuracy | Systolic ± 3 mmHg, Diastolic ± 3 mmHg, Pulse ± 5% of the value shown |
Measurement inaccuracy | Max. permissible standard deviation according to clinical testing: Systolic 8 mmHg / Diastolic 8 mmHg |
Memory | 2 x 60 memory spaces |
Dimensions | L 80.5 mm x W 69.5 mm x H 25 mm |
Weight | Approximately 116 g (without batteries, with cuff) |
Cuff size | 135 to 215 mm |
Permissible operating conditions | +5°C to +40°C, 15-90% relative humidity (non-condensing), 700-1060 hPa ambient pressure |
Permissible storage and transport conditions | -20°C to +60°C, ≤ 93% relative humidity (non-condensing) |
Power supply | 2 x 1.5V AAA batteries |
Battery life | For approx. 150 measurements, depending on levels of blood pressure and pump pressure |
Software version | A01 |
Data transfer | 2402 MHz – 2480 MHz frequency band Transmission power max. 7 dBm The blood pressure monitor uses Bluetooth® low energy technology Compatible with Bluetooth® ≥ 4.0 smartphones/tablets |
The serial number is located on the device or in the battery compartment.
Technical information is subject to change without notification to allow for updates.
Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as "Beurer") provides a warranty for this product.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.