Check that the exterior of the cardboard delivery packaging is intact and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address.
1x upper arm blood pressure monitor
1x easyClip upper arm cuff (22–42 cm)
1x instructions for use
1x storage bag
4 x 1.5V AA LR6 batteries
The following symbols are used on the device, in these instructions for use, on the packaging and on the type plate for the device:
Isolation of applied parts Type BF Galvanically isolated applied part (F stands for "floating"); meets the requirements for leakage currents for type B | |
Direct current The device is suitable for use with direct current only | |
Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE | |
Do not dispose of batteries containing hazardous substances with household waste | |
Separate the packaging elements and dispose of them in accordance with local regulations. | |
Marking to identify the packaging material. A = Material code, B = Material number: 1-7 = Plastics, 20-22 = Paper and cardboard | |
Separate the product and packaging elements and dispose of them in accordance with local regulations. | |
Manufacturer | |
Storage/Transport | Permissible storage and transport temperature and humidity |
WARNING Warning notice indicating a risk of injury or damage to health | |
IMPORTANT Safety note indicating possible damage to the device/accessory | |
Note Note on important information | |
Observe the instructions Read the instructions before starting work and/or operating devices or machines | |
Operating | Permissible operating temperature and humidity |
Serial number | |
IP 22 | Device protected against foreign objects ≥ 12.5 mm and against water dripping at an angle |
This product satisfies the requirements of the applicable European and national directives. |
The blood pressure monitor is intended for the fully automatic, non-invasive measurement of arterial blood pressure and pulse values on the upper arm.
It is designed for self-measurement by adults in the home environment.
The blood pressure measurement is suitable for adult users whose upper arm circumference is within the range printed on the cuff.
The user can record their blood pressure and pulse values quickly and easily using the device. The recorded values are classified according to internationally applicable guidelines and evaluated graphically. Furthermore, the device can detect any irregular heart beats that occur during measurement and inform the user via a symbol in the display. The device saves the recorded measurements and can also output average values of previous measurements.
The recorded data can provide healthcare service providers with support during the diagnosis and treatment of blood pressure problems, and therefore plays a part in the long-term monitoring of the user's health.
In the event of hypertension or hypotension, the user can independently monitor their blood pressure and pulse values as well as arrhythmia at home. However, the user does not need to be suffering from hypertension or arrhythmia in order to use the device.
Contraindications
General warnings
General precautions
Measures for handling batteries
Notes on electromagnetic compatibility
Information on the display:
It is essential that you set the date and time. Otherwise, you will not be able to save your measured values correctly with a date and time and access them again later.
There are two different ways to access the menu from which you can adjust the settings:
Hour Format
The hour format flashes on the display.
Date
The year flashes on the display.
The month flashes on the display.
The day flashes on the display.
If the hour format is set as 12h, the day/month display sequence is reversed.
Time
The hour flashes on the display.
The minute flashes on the display.
You can also operate this device with a mains part (not included in delivery). The mains part can be obtained from specialist retailers or from the service address using order number 071.95. However, before connecting the device with the mains part, please ensure that you have removed the batteries from the device. During mains operation, there must not be any batteries in the battery compartment, as this could damage the device.
Please ensure the unit is at room temperature before measuring. The measurement can be performed on the left or right arm. Circulation in the arm must not be restricted by tight clothing or similar.
Ensure that your arm is not pressing on the line.
Blood pressure may vary between the right and left arm, which may mean that the measured blood pressure values are different. Always perform the measurement on the same arm. If the values between the two arms are significantly different, please consult your doctor to determine which arm should be used for the measurement.
The device may only be operated with the original cuff. The cuff is suitable for an arm circumference of 22 to 42 cm.
Press the SET setting button. Select the relevant user memory ( or ) by pressing the -/+ function buttons. You have 2 memories, each with 100 memory spaces, to enable the separate storage of measurements for 2 different people. Confirm your selection with the START/STOP button or wait for 3 seconds. Your selection is then automatically stored.
As described above, attach the cuff and adopt the posture in which you want to perform the measurement.
The blood pressure monitor will begin measurement automatically after 5 seconds.
The cuff automatically inflates. The measurement itself is taken during the inflation phase.
As soon as a pulse is found, the pulse symbol will be displayed.
You can cancel the measurement at any time by pressing the START/STOP button .
• Systolic pressure, diastolic pressure and pulse measurements are displayed.
Cardiac arrhythmia:
This device can identify potential disruption of the heart rhythm when measuring and, if necessary, indicates this after the measurement with the symbol .
This can be an indicator for arrhythmia. Arrhythmia is a condition in which the heart rhythm is abnormal because of flaws in the bioelectrical system that regulates the heartbeat. The symptoms (skipped or premature heart beats, pulse being slow or too fast) can be caused by factors such as heart disease, age, physical make-up, excess stimulants, stress or lack of sleep. Arrhythmia can only be determined through an examination by your doctor.
If the symbol is shown on the display after the measurement has been taken, repeat the measurement. Please ensure that you rest for 5 minutes beforehand and do not speak or move during the measurement. If the symbol appears frequently, please consult your doctor.
Self-diagnosis and treatment based on the measurements can be dangerous. Always follow your doctor's instructions.
Risk indicator:
The measurements can be classified and evaluated in accordance with the following table.
However, these standard values serve only as a general guideline, as the individual blood pressure varies in different people and different age groups etc.
It is important to consult your doctor regularly for advice. Your doctor will tell you your individual values for normal blood pressure as well as the value above which your blood pressure is classified as dangerous.
The bar chart on the display and the scale on the device show which category the recorded blood pressure values fall into. If the values of systole and diastole fall into two different categories (e.g. systole in the High normal category and diastole in the Normal category), the graphical classification on the device always shows the higher category; for the example given this would be High normal.
Blood pressure value category | Systole (in mmHg) | Diastole (in mmHg) | Action | |
Level 3: severe hypertension | red | ≥ 180 | ≥ 110 | Seek medical attention |
Level 2: moderate hypertension | orange | 160 – 179 | 100 – 109 | Seek medical attention |
Level 1: mild hypertension | yellow | 140 – 159 | 90 – 99 | Regular monitoring by doctor |
High normal | green | 130 – 139 | 85 – 89 | Regular monitoring by doctor |
Normal | green | 120 – 129 | 80 – 84 | Self-monitoring |
Optimal | green | < 120 | < 80 | Self-monitoring |
User memory
The results of every successful measurement are stored together with the date and time. If there are more than 100 measurements, the oldest measurements are lost.
Average values
Press the M memory button.
lights up on the display. The average value of all saved measured values in this user memory is displayed.
Press the M memory button.
lights up on the display. The average value of the morning measurements for the last 7 days is displayed (morning: 5 a.m. – 9 a.m.).
Press the M memory button.
lights up on the display. The average value of the evening measurements for the last 7 days is displayed (evening: 6 p.m. – 8 p.m.).
Individual measured values
When the M memory button is pressed again, the last individual measured values in each case are displayed with the date and time (for example measurement 03).
When the memory button M is pressed again, you can view your individual measured values.
To switch the device off again, press the START/STOP button . If you forget to switch off the unit, it will switch off automatically after 1 minute.
You can exit the menu at any time by pressing the START/STOP button .
Deleting measured values
To delete the memory of the selected user memory, press the M memory button in switched-off state. The average value of all measurements appears on the display; in parallel, lights up. Press and hold down both function buttons -/+ simultaneously for 5 seconds.
appears on the display. All the values in the selected user memory have now been deleted.
Accessories and replacement parts are available from the corresponding service address (according to the service address list). Please state the corresponding order number.
Designation | Item number and/or order number |
easyClip universal cuff (22–42 cm) | 164.161 |
Mains part (EU) | 071.95 |
Mains part (UK) | 072.05 |
Error message | Possible cause | Solution |
Unable to record a pulse. | Please wait one minute and repeat the measurement. Ensure that you do not speak or move during the measurement. | |
The cuff was not attached correctly. | Please observe the information in chapter 7 under the heading "Attaching the cuff". | |
An error occurred during measurement. | Please wait one minute and repeat the measurement. Ensure that you do not speak or move during the measurement. | |
An error occurred while pumping up the cuff. | Please take another measurement to check whether the cuff can be correctly inflated. Make sure that neither your arm nor other heavy objects are pressing on the line, and that the line is not bent. | |
System error | Please contact customer service. | |
The batteries are almost empty. | Insert new batteries into the device. |
Model no. BM 51
Type | BPM51 |
Measurement method | Oscillometric, non-invasive blood pressure measurement on the upper arm |
Measurement range | Cuff pressure 0–300 mmHg, systolic 60–255 mmHg, diastolic 40–200 mmHg, pulse 40 –199 beats/minute |
Display accuracy | Systolic ± 3 mmHg, diastolic ± 3 mmHg, pulse ± 5% of the value shown |
Measurement uncertainty | Max. permissible standard deviation according to clinical testing: Systolic 8 mmHg / diastolic 8 mmHg |
Memory | 2 x 100 memory spaces |
Dimensions | L 138 mm x W 103 mm x H 46 mm |
Weight | Approximately 570 g (without batteries, with cuff) |
Cuff size | 22 to 42 cm |
Permissible operating conditions | + 10°C to + 40°C, ≤ 85% relative humidity (non-condensing), 700 hPa–1060 hPa environmental pressure |
Permissible storage conditions |
|
Power supply | 4 x 1.5 V AA batteries |
Battery life | For approx. 500 measurements, depending on levels of blood pressure and inflation pressure |
Classification | Internal supply, IP22, no AP or APG, continuous operation, application part type BF |
The serial number is located on the device or in the battery compartment.
Technical information is subject to change without notification to allow for updates.
Model no. LXCP12-006060BEH
Input | 100 – 240 V, 50 – 60 Hz, 0.5 A max |
Output | 6 V DC, 600 mA, in conjunction with Beurer blood pressure monitors only |
Manufacturer | Shenzhen Iongxc power supply co., ltd. |
Protection | The device is double protected and has a primary-side cutout switch which disconnects the device from the mains in case of malfunction. Ensure that you have removed the batteries from the battery compartment before you use the mains part. |
Polarity of the DC voltage connection | |
Insulated/protection class 2 | |
Housing and protective covers | The housing of the mains part protects users from touching live parts or parts that could be live (for example with finger, needle, checking hook). Do not touch the patient and the output connector of the AC/DC mains part at the same time. |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.