Making Gas Connections; Making Electrical Connections (12 Volt D.c.); Making Electrical Connections 120 Volts A.c - Suburban SW6P Installation And Operation Manual

Direct vent gas water heater
Table of Contents

Advertisement

Figure 4
MODELS:
SW6P
SW6PE
SW6PR
SW6PER
SW6D
SW6DE
IV. MAKING GAS CONNECTIONS
A.
Connect a 3/8" gas supply line to the 3/8 flare fitting at gas valve located in
the control housing.
NOTE: It will be necessary to remove the grommet from the control housing,
make the gas connection at the valve, then reinstall grommet.
WARNING: It is imperative that grommet and gas line through
grommet be caulked air tight. If not tightly sealed, moisture and
potential harmful flue products could vent through opening and into
living area of trailer. (See Figure 7)
B. Turn on gas and check for leaks, using a soap and water solution. Correct
even the slightest leak immediately.
WARNING! Do not use an open flame to check for leaks!
V. MAKING ELECTRICAL CONNECTIONS
12 VOLTS D.C.
A.
Applicable to following models: SW6D,SW6DE, and SW6DM.
B.
Refer to Figure 2 for location of D C. junction box on models SW6D and
SW6DE. Refer to Figure 6 for location of D C. junction box on model SW6DM.
C.
The electrical connections must be made in accordance with local codes
and regulations. In the absence of local codes and regulations, refer to the latest
edition of the National Electrical Code ANSI/NFPA No. 70.
In Canada, the electrical installation should conform with CSA standard CSA
C22.2 No. 148/Z240.6.2 Electrical Requirements for Recreational Vehicles and
CSA C22.1 Canadian Electrical Code Part 1 when installing the unit in
recreational vehicles and mobile homes respectively.
Au Canada, I'installation electrique doit satisfaire a la norme ACNOR 22.2 N
148/Z240.6.2 Exigences electriques des vehicules de loisir ou a la norme
ACNOR C22.1
Premeire Partie du Code Electrique Canadien selon que
I'appareil est installe dans un vehicule de loisir ou une maison rouiante.
D.
Make sure the water heater is filled with water before making the electrical
connections.
E.
Make the 12 Volt D.C. electrical connections following the wiring diagram
illustrated in Figure 8.
12 VDC. ONLY
IFANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER
HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18
GA., 105* C WIRE OR IT'S EQUIVALENT.
(+)
MODULE
BD.
DISCONNECT POWER SUPPLY BEFORE SERVICING
THERMOSTAT AND HI-LIMIT UNDER ACCESS COVER.
WIRING DIAGRAM
12 V DC._340461
si
un desffls electriques livres avec le chauffe-eau doit etre
rernplace, utiliser a cet effet un fit 1ft GA. 105*C ou equivalent.
Figure 8
VI. MAKING ELECTRICAL CONNECTIONS
120 VOLTS A.C.
A.
Applicable to following models: SW6PE, SW6PER,and SW6DE
B.
Refer to Figure 2 for location of A.C. junction box.
C.
The electrical connections must be made in accordance with local codes
and regulations. In the absence of local codes and regulations, refer to the latest
edition of the National Electrical Code ANSi/NFPA No. 70.
In Canada, the electrical installation should conform with CSA standard CSA
C22.2 No. 148/Z240.6.2 Electrical requirements for Recreational Vehicles and
CSA C22.1 Canadian Electrical Code Part 1 when installing the unit in
recreational vehicles and mobile homes respectively.
Au Canada, I'installation electrique doit satisfaire a la norme ACNOR 22.2 N
148/Z240.6.2. Exigences electriques des vehicules de loisir ou a la norme
ACNOR C22.1
Premiere partie du Code electrique Canadien selon que
I'appareil est installe dans un vehicule deloisir ou une maison rouiante.
Figure 7