Internal Wiring - Re-Verber-Ray MP3 Series Insert Manual

Table of Contents

Advertisement

MP3
Series
Internal Wiring Diagram
Before field wiring this appliance - Check existing wiring; replace if necessary.
Note: If any of the original wire supplied with the appliance must be replaced, it must be replaced with wiring
material having a rating of at least 600 V, 105°C.
Figure 2.1
Internal Wiring Diagram
GAS VALVE
BL
BK
VALVE
INDICATOR
LIGHT
BK
N
L1
BK
W
GN
1 2 3 4 5 6
BK
W
BLOWER
LLWT382a
13 14 15 16 17 18
MP3 SERIES
BK
GN
GROUND
W
NEUTRAL
R
VALVE
W
L2 (NEUTRAL)
O
THERMOSTAT
BK
L1
BK
SIC1
BR
PROBE
BL
Y
BK
BL
Y
W
GAS VALVE RELAY
BK
ENABLE RELAY
R
MODULATING
THERMOSTAT
CONTROLLER
7
8 9
10 11 12
W
N
BK
L
BK
N
BK
F
ALM+
ALM-
T3
19 20 21 22 23 24
T2
T1
RTN
G
Br
IGNITION
MODULE
F.C. TEST PINS
L1
BK
BK
BK
W
Y
TRANSFORMER
BL
BK
BK
P.S. INDICATOR
LIGHT
BR
O
W
N.C.
N.O.
PRESSURE
PRESSURE
SWITCH
SWITCH
IGNITER
FLAME SENSOR
LLWT382a
MP3 SERIES
7
0
LLWT382a-XM-01/24 (XXX)
2.0
Installation
Internal Wiring Diagram
N
MODULATING
CONTROLLER
GN
W
BK
BK
BK
W
BLOWER
GN
GROUND
W
NEUTRAL
R
VALVE
W
L2 (NEUTRAL)
O
THERMOSTAT
BK
L1
BK
SIC1
BR
PROBE
W
N
L
N
F
ALM+
ALM-
T3
T2
T1
RTN
G
Br
IGNITION
MODULE
F.C. TEST PINS
0

Advertisement

Table of Contents
loading

Table of Contents