RANGER 305D
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.
ENGINE AND IDLE PROBLEMS
POSSIBLE AREAS OF
MISADJUSTMENT(S)
C UTION
F 18
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
RECOMMENDED
COURSE OF ACTION
7. IF THE SOLENOID DOES NOT HOLD IN
THE LOW IDLE POSITION, REMOVE
PLUG P6 FROM CONTROL PC BOARD
AND WAIT FOR ABOUT 30 SECONDS.
8. IF THE ENGINE DROPS TO LOW IDLE,
CHECK FOR DAMAGE OR A BUILDUP
OF CONDUCTIVE MATERIALS ON OR
AROUND THE BYPASS FILTER
ASSEMBLY AND THE OUTPUT
TERMINALS. SEE WIRING DIAGRAM.
9. NOTE: THE BYPASS FILTER ASSEMBLY IS
CONNECTED BETWEEN THE OUTPUT
TERMINALS. SEE WIRING DIAGRAM.
10. IF THE ENGINE STILL DOES NOT DROP
TO LOW IDLE, THE CONTROL PC
BOARD IS PROBABLY
DEFECTIVE. REPLACE IT.