F-21
MAIN GENERATOR SHUNT FIELD WINDING TEST (continued)
PIN 5
5. Locate the blue (U) (pin 3) and the brown (N)
(pin 5) leads in the harness plug.
Figure F.6.
6. Using the volt/ohmmeter, measure the resis-
tance between the blue and the brown lead.
Normal resistance is approximately 40
ohms.
7. Also measure the resistance from either
lead (blue or brown) to ground. This resis-
tance should be at least 500,000 ohms.
8. If the test does not meet the resistance
specifications, then check the harness plug
for loose connections or shorted leads.
TROUBLESHOOTING & REPAIR
FIGURE F.6 – PLUG P10 PIN ASSIGNMENTS
TAB
See
PIPELINER® 200
PIN 3
9. If the plug and associated leads are okay,
the shunt field coils may be faulty. Replace
the shunt field coils.
10. If the test does meet the resistance specifi-
cations, the main shunt coils are okay.
11. Replace plug P10, making sure the leads
and plug are secure.
12. After the test and repairs are completed,
close and latch the right side door.
F-21