Troubleshooting - Beko B3WFT4822MG User Manual

Table of Contents

Advertisement

NOTICE:
Foreign substances left in the
pump filter may damage your
product or may cause noise prob-
lem.
In regions where freezing is pos-
sible, the tap must be closed, sys-
tem hose must be removed and the
water inside the product must be
drained when the product is not in
use.
After each use, turn off the tap to
which the mains hose is connected.
In order to clean the dirty filter and drain
the water:
1. Unplug the product to cut off the supply
power.
Temperature of the water inside the
product may rise up to 90 ºC. To
avoid the risk of scalding, clean the
filter after the water inside the
product is cooled down.
2. Open the filter cover.

8 Troubleshooting

Please read the "Safety Instruc-
tions" section first!
Programmes do not start after the load-
ing door is closed.
• Start / Pause / Cancel button is not
pressed. >>> Press Start / Pause / Cancel
button.
3. Follow the below procedures in order to
drain water.
If the product has an emergency water
draining hose, in order to drain the wa-
ter:
• Pull the emergency draining hose out of
its seat.
• Place the end of the hose in a large con-
tainer. Drain the water into the container
by pulling out the plug at the end of the
hose. When the container is filled, close
the end of the hose with the plug. Drain
all water by repeating the procedure spe-
cified above after draining the container.
• When the water drain is finished, close
the end with the plug again and fix the
hose in its place.
• Unscrew the pump filter.
1. Clean any residues inside the filter as
well as fibres, if any, around the pump
impeller region.
2. Replace the filter.
3. If the filter cap is composed of two
pieces, close the filter cap by pressing
on the tab. If it is one piece, seat the
tabs in the lower part into their places
first, and then press the upper part to
close.
• It may be difficult to close the loading
door in case of excessive loading. >>>
Reduce the amount of laundry and make
sure that the loading door is closed prop-
erly.
Programme cannot be started or selec-
ted.
• The product has switched to self-protec-
tion mode due to a supply problem (line
voltage, water pressure, etc.). >>> De-
pending on the product model, select an-
EN / 32

Advertisement

Table of Contents
loading