National Instruments SCXI-1129 User Manual page 40

256 crosspoint high-density matrix
Hide thumbs Also See for SCXI-1129:
Table of Contents

Advertisement

B1C0–B1C15
B1C16–B1C31
B1R0–B1R3
B2C0–B2C15
B2C16–B2C31
B2R0–B2R3
SCXI-1339
Terminal
Block
B1R0 = Bank 1 Row 0
B1C0 = Bank 1 Column 0
Each row and column consists of two wires. One for source (+) and one for return (–).
Note: The analog bus relays have a built-in safety interlock. For safety reasons, they cannot be closed unless
a terminal block is connected.
© National Instruments Corporation
16 columns
4 x 16 Matrix
4 rows
Relays
16 columns
4 x 16 Matrix
4 rows
Relays
16 columns
4 x 16 Matrix
4 rows
Relays
16 columns
4 x 16 Matrix
4 rows
Relays
128 K x 8 SRAM
Scan List Memory
SCANADVD
Digital Interface
EXTRIGIN
Calibration EEPROM
Front Signal
Connector
SCXI-1129
Module
Connection Relays
0
1
2
3
0
1
2
3
0
1
2
3
0
1
2
3
and Control
(FPGA)
×
Figure 2-5. 4
32 Matrix Configuration
2-7
Chapter 2
Using the SCXI-1129
Analog Bus Relays
Voltage
0
AB0
1
AB1
2
AB2
Connector
3
AB3
Com0
Digital
Com1
Comm.
Voltage
Com2
Com3
Connector
SCXIBus
SCXIBus
Interface
Connector
SCXI-1129 User Manual
High-
Rear
Signal
Low-
Rear
Panel
Signal

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scxi-1357

Table of Contents