2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
• You can set a snug point detection level from the setting parameter input screen.
• Enter a desired value in the "Snug Point Detection Level" input field.
CAUTION
• Set a snug point detection level from "1".
Setting a snug point detection level from "2–7" may result in cracking or deformation of the target
material because of high tightening torque.
• If the tool stops before the snug point at a snug point detection level of "1", set the snug point
detection level to "2–7".