HE365A POWERED FLOW-THROUGH HUMIDIFIER WITH AGION™ ANTIMICROBIAL
12. Snap the water nozzle back on the tray.
13. Be sure the marked end of the pad is facing up.
Place the tray on the new pad.
14. Place humidifier pad assembly in humidifier
housing. Be sure water feed tube is placed in
guide slots.
15. Replace the humidifier cover.
16. See Checking Your Humidifier for Proper Opera-
tion section to verify operation.
End of Humidification Season
The humidifier needs to be cleaned and shut off at the
end of the heating season. See Every 1 to 3 Months
section, steps 1 through 15, to shut down for the
season.
FEED TUBE NOZZLE
WATER
DISTRIBUTION TRAY
HUMIDIFIER
PAD ASSEMBLY
THUMB
SCREW
IMPORTANT
Be sure humidifier power is off.
Vacation
The humidifier water supply and your humidity
control can be turned off. Turn on humidifier water
supply and reset your humidity control when you
return.
CHECKING YOUR
HUMIDIFIER OPERATION
After winter startup or servicing, check the humidifier
operation:
1. Turn on the humidifier power and water supply.
2. Turn Control to highest setting or to test posi-
tion; set thermostat to 10°F (6°C) above room
temperature.
NOTE: The H1008A Automatic Humidity Control
stays in test mode for thirty minutes. Then it
automatically resets to the maximum frost
Resideo Inc., 1985 Douglas Drive North,
Golden Valley, MN 55422
www.resideo.com
33-00510EF—01 M.S. 11-19 | Printed in United States
This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502
©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.
HUMIDIFIER
HOUSING
COVER
ASSEMBLY
Fig. 1.
factor setting. If system checkout is not com-
pleted in thirty minutes, test mode can be
extended by turning dial setting back and
then returning it to test mode.
3. Observe that water is flowing out of the drain
hose.
NOTE: The furnace blower must be on to activate
the humidifier.
4. Reset thermostat and Humidifier Control to
comfortable setting or to desired frost factor
setting for automatic operation.
TROUBLESHOOTING YOUR
HUMIDIFIER
Problem
Low
humidity
M14671A
High
humidity
What to Look
for
Furnace blower
• Reset circuit
not operating.
breaker or replace
fuse.
• Check that the
furnace power is
on.
• Check all external
wiring
connections.
• Check humidity
control setting.
• Call a heating
contractor.
Rapid air
• Keep doors and
changes. Drafts
windows closed.
(cold air is dry
• Close fireplace
and is an added
damper if not
load to
using.
humidifier).
• Minimize exhaust
fan running time.
• Seal around doors
and windows.
Condensation
• Turn off humidity
on walls.
control and water
until
condensation is
completely
evaporated.
Heavy
• Turn humidity
condensation on
control low
windows.
enough to
eliminate bath
and cooking
condensation
moisture. If
moisture persists,
more ventilation is
needed.
What to Do