the display screen will display "E3", the compressor will automatically top running.At
this time, the water plug at the drain under the machine can be removed, and the water
can be discharged through the drain pipe.The machine returned to normal operation.
6. Temperature display conversion
Long press the mode key to switch the display Fahrenheit and Celsius.

CLEANING AND STORAGE

-Make sure that the appliance is disconnected from the power supply before cleaning.
-Do not use abrasive detergents or products that could damage the appliance. Simply
clean the surface with a wet cloth.
-Do not immerse the appliance in water or any other liquid.
-Store the appliance in a safe and dry place.
1.Air Filter
- If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once
every two weeks.
- Dismounting: Open the air inlet grille and take off air filter.
- Cleaning: Clean the air filter with neural detergent in lukewarm (40ºC) and dry it
up in the shade.
- Mounting: Putting the air filter into the inlet grille, replace the components as they
were.
2. Clean the Air-conditioner Surface
First, clean the surface with a neutral detergent and wet cloth, and then wipe it with
a dry cloth.
Trouble Shooting
Troubles
1. Unit does not start when
pressing power button
Possible Causes
- Water full indicator lamp
blinks, and water
.
tank is full.
- Room temperature is
higher than the setting
temperature.
heating mode).
- Room temperature is
lower than the setting
temperature.
mode)
Suggested Remedies
Dump the water out of the
water tank.
Reset the temperature.
(Electric
Reset the temperature.
(Cooling
English