Connecting the System
Connecting with the
ADAT & BRC
(Connection
2)
Wordclock master: WZ-AD96/96M
AO Converter
•
Connection
1. Connect between Wordclock-Out on the AD converter and WCK In on the
DA converter with a BNC cable. In addition connect between WCK THRU
on the DA converter and 48 kHz In on the BRC with a BNC cable. Note
that inside the AD converter both CN907 and 908 jumpers are set to
"OUT" positions.
2. Connect between ADAT Out on the AD converter and Digital-In on the
ADAT with an optical cable to transmit 1-8 channel digital audio data.
3. Connect between DIGITAL Out on the ADAT and ADAT-In on the DA
converter with an optical cable to monitor the sound.
4. Connect between Remote Out to ADAT on the BRC and SYNC-ln on the
ADAT .with a SYNC cable to control ADA!' remotely and to take
synchronization.
•
Setting
1. On the AD converter, select "CRYSTAL" by pressing the CLOCK button to
let it work as the wrordclock master. In addition select a sampling
frequency by pressing the FREQ button. Note that if 88.2 or 96 kHz is
selected , move the DIP switch #6 to On to keep sending 44.1 or 48 kHz
wordclock to the BRC and ADAT.
2. Set the DIP switch on the AD converter #7 to Off and #8 to On to meet
the REF level to -16 dBFS. See "REF Level Setting".
3. On the AD converter, select output channels: 1-4 or 5-8: after entering the
SHIFT operation mode if 88.2 or 96 kHz is used. The selected channel
outputs will be recorded on the ADAT's tracks: output channels "1, 2, 3
and 4" or "5, 6, 7 and 8" will be recorded onto track 1/2, 3/4, 5/6 and 7/8
respectively.
(1) To enter the SHIFT operation mode press the WORD LENGTH button
for 2 second or more.
(2) Press the FREQ button to select output channels. The FREQ LEDs
indicate the selection.
CH 1-4: The FREQ LED 44.1k/88.2k lights.
CH 5-8: The FREQ LED 48k/96k lights.
4. On the BRC, select "48 k Input" by pressing the EXT SYNC switch to sync
to the wrordclock.