Starter System
NOTE: Do not crank engine continuously for more than 10 seconds. Allow a 60 second cool down period between
starting attempts. Failure to follow these guidelines can burn out starter motor.
NOTE: If engine develops suffi cient speed to disengage starter but does not keep running (a false start), engine
rotation must be allowed to come to a complete stop before attempting to restart engine. If starter is engages
while fl ywheel is rotating, starter pinion and fl ywheel ring gear may clash and damage starter.
NOTE: If starter does not crank engine, shut off starter immediately. Check condition of inline fuse and do not make
further attempts to start engine until condition is corrected.
NOTE: Do not drop starter or strike starter housing. Doing so can damage starter.
Engines in this series use inertia drive electric starters or retractable starters. CH245, CH255, CH270 inertia drive
electric starters are not serviceable.
Troubleshooting-Starting Diffi culties
Condition
Starter does not energize.
Starter energizes but turns
slowly.
Electric Starting System Tests
1. Test battery on unit.
a. Connect a DC voltmeter across battery terminals
and read battery voltage (key switch OFF).
b. Turn key switch to start position and read battery
voltage again. Turn switch OFF.
Condition
Voltage less than 12 volts. Charge battery.
Battery voltage should not
fall below 9 volts during
cranking.
50
Possible Cause
Battery
Wiring
Starter Switch
or Solenoid
Battery
Wiring
Transmission
or
Engine
Conclusion
If it does, battery may be
faulty or there may be a
short in starting circuit.
Have battery load tested.
If battery passes load test,
check circuitry.
KohlerEngines.com
Check specifi c gravity of battery. If low, recharge or replace
battery as necessary.
Check fuse condition.
Clean corroded connections and tighten loose connections.
Replace wires in poor condition and with frayed or broken
insulation.
Check switch or relay operation. If starter cranks normally,
replace faulty components.
Check specifi c gravity of battery. If low, recharge or replace
battery as necessary.
Check for corroded connections, poor ground connection.
Make sure clutch or transmission is disengaged or placed
in neutral. This is especially important on equipment with
hydrostatic drive. Transmission must be exactly in neutral to
prevent resistance which could keep engine from starting.
Check for seized engine components such as bearings,
connecting rod, and piston.
2. Remove electric starter cover panel and check fuse
inside plastic holder. Fuse outside holder is a spare.
Condition
Fuse is blown.
3. Disconnect blue relay lead. Be sure transmission is
in neutral and PTO is OFF. Connect one end of a
jumper lead to positive terminal of battery. Connect
other end to terminal of relay.
Condition
Relay engages and starter
begins to crank.
Conclusion
Conclusion
Check for a wiring
problem (bare wire, short
circuit). Correct problem
and replace fuse. Try to
start engine. If it still won't
start, go to step 3.
Conclusion
Key switch is faulty, or
there is a wiring problem
to/from key switch. Check
wiring and test key switch
circuits with an ohmmeter.