Rectifi ed Only (non-regulated) Systems
Some engines are equipped with a rectifi ed only, non-regulated charging system, with output ranging from 3 amps to
4 amps. Rectifi er is normally connected to engine with a matching wiring harness and secured inside control panel.
Grounding is achieved through wiring harness. Rectifi er converts AC voltage coming from stator to DC voltage only.
Wiring Diagram-3/4 Amp Charging System, Rectifi ed Only
D
E
A
Diode
E
Oil Float Switch
I
Relay
17 690 01 Rev. L
C
A
B
G
F
B
Stator
F
Oil Control Module
J
Battery Fuse
KohlerEngines.com
J
I
H
C
Ignition Module
G
Key Switch
K
12 Volt Battery
Electrical System
K
D
Spark Plug
H
Starter Motor
47